User's Manual
the motor in the appropriate direction. Pressing and releasing either Open or Close with the motor running will stop
the motor.
Learning into a Z-wave network/transmitter
Follow the instructions for the z-wave controller into which you wish to learn the motor to put the controller into
learn mode. Next press and release the Z-Wave “learn” button on the motor. The Z-Wave LED on the motor will blink
once green. The controller should respond with an indication that the motor was successfully learned. The motor
should be learned into the controller as a slave with generic device class “Multilevel Switch”, specific device class
“Multiposition Motor”.
Setting Limits Automatically
To set limits automatically, press and releasing the open or close button and allow the motor to run to stall. Press
and release the button for the opposite direction and allow the motor to run to stall. Allowing the motor to run to
the end in both directions will record those positions as a limit. Automatic limit setting adds a position offset of 1/8”
(3.2mm) from the stall position at the close limit to avoid the loud banging caused by hitting the end of the drapery
track. It also adds a position offset of 2” (50mm) from the stall position at the open limit to avoid the unsightly
appearance of the drapery bunching together.
Setting Limits Manually
To set a limit manually, operate the motor in the appropriate direction by pressing and releasing the open or close
button, then stop it at the desired limit position by pressing and releasing either open or close. Repeat as necessary
until the motor is stopped in the desired limit position. If you are setting the limit for the drapery open position, press
and hold the open button for 10 seconds. If you are setting the limit for the drapery closed position, press and hold
the close button for 10 seconds. Pressing and holding either open or close for 10 seconds with the motor running
will be ignored. If the limit being set was previously defined, its previous setting is overwritten and the most recently
defined limit takes precedence.
Note
In the event of the drapery motor losing power, if the drape is moved physically by hand, the limit setting will be
incorrect, and the limits will need to be reset as per above. Follow the procedure for clearing the limits and then
follow the procedure for setting limits automatically or manually.
Administrative Options
Entering Administration Mode
Press and hold both Open and Close for 10 seconds. The Motor LED will light solid. The controller will remain in
Administrative mode for 10 seconds after releasing both buttons. After 10 seconds the LED will extinguish indicating
the controller has exited administrative mode.
Reverse Motor
1. Enter administrative mode
2. Press and release Open while in administrative mode to toggle the direction of the motor. This will be
indicated by a short flash on the motor LED. Toggling the direction will also clear any previously defined
limits, and the Motor LED will flash after exiting administration mode to indicate the limits have been cleared.