User's Manual Part 3

When moving the selected Time (X) Reference line, it can be moved past
other cursors to any location on the Data Graph.
When a Time (X) Reference line is moved to a new position, it snaps to the closest real
Time (X) value. Notice on highly magnified graphs that the line jumps from point to point.
The values in the Data Table are automatically updated to reflect the new position.
5.5.9.5. Align Profile Peaks
If sensors are placed so they enter and exit machine zones at different times, the resulting
Data Plots lag behind one another. The Align Profile Peaks command automatically
aligns the Time (X) axis maximum peak values for each Data Plot so the results can be
easily compared during analysis.
This is available in both Engineer & Verify Modes.
To align profile peaks:
A conveyor speed must be set to properly use this command. Refer to topic
Software>Menus>Machine>Set Machine Information or Software>Page
Tabs>Profile>Data Graph>Conveyor Speed Indicator for more details.
1) On the Profile menu, click Align Profile Peaks the channel lag values are
automatically calculated, and the Data Plots adjust to reflect them. A check mark
appears to the left of the command indicating the software is in Align Profile Peaks
mode. Repeat this step to disable the command.