User's Manual Part 3

Wireless RF Option:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
SuperM.O.L.E.® Gold 2 Radio:
Type:
IEEE 802.15.4 ZigBeetwo way
Frequency:
2.45 gHz
Power:
1mW (0dbm)
Range:
6.5 meters (20ft)*
Wireless Antenna:
Temperature:
250ºC (500ºF)
Exposed Material:
Teflon insulation
Connector:
MMCX Right Angle
USB Transceiver:
Type:
IEEE 802.15.4 ZigBeetwo way
Antenna:
Internal fractal chip
* The range of the SuperM.O.L.E.® Gold 2 RF system varies with the RF environment. Under ideal
conditions, the range may be 6.5 meters [20 feet] and in some situations it may only be a few meters. Refer to
topic Basics>Wireless RF Option Setup
Thermocouple Specifications:
Thermocouples: Type K, Mini-Connector, Glass insulated. (Other insulation types available.)
THERMOCOUPLE RESPONSE TIME
Wire Size
Still Air
800/100°F
60 Ft./Sec. Air
800/100°F
Still H2O
200/100°F
.005 in.
1.0 sec.
0.08 sec.
0.04 sec.
Environmental Limitation Specifications:
SuperM.O.L.E.® Gold 2 Profiler:
Maximum relative humidity 80% RH from 0°C to 31°C, decreasing linearly to 17% RH at 50°C.
Pollution Degree 2 (Normally only dry pollution, but with temporary conductivity caused by condensation)
Power Pack Charger:
Temperature: (Operation) 0 to +45°C (32 to 113°F)
Temperature: (Non-Operation) -20 to +75°C (-4 to 167°F)
Humidity: (Operation) 20 to 90%
NOTE:Tests have shown that because of the sensitive nature of the measurement and logic circuits, the