5.4.4.4. Target 10-OK
Target 10-OK is a simple yet powerful way to achieve the pursuit of the perfect profile.
The user specifies requirements for the profile initial slope, soak, TAL (time above
liquidous), peak parameter and the channels that these requirements are to be applied.
Then the software automatically calculates a single go/no-go number.
A Target 10 specification is created using the Create Target 10 Specification workflow
wizard. Refer to topic Menus>Wizards Menu>Create Target 10 Specification for more
information.
The features associated with Target 10-OK can only be used when in
Engineer mode. They can only be viewed when in Verify mode.
Target 10-OK feature allows the user to answer the following questions:
1) How do I specify a good profile?
• Answer: Based on the selected process specification and specification limits, the
user can set the four process parameters (Initial slope, Soak, TAL & Peak).
2) How do I know I have a good profile?
• Answer: Based on the specified settings, the active individual parameter indicators
(Slope, Soak, TAL & Peak) display the normalized values. Once Target 10-OK
numbers are calculated, they reduce the evaluation of the displayed data run
profile to a single number. This number appears in a two state (Red-Green)
indicator with the worst condition number appearing in the Final Indicator symbol.
A score of less than 0.0 is bad, 0.0-5.0 is good, 5.1-9.9 better and 10.0 being the
perfect score.
3) How can I improve the profile?
• Answer: Using the Prediction Tool, the user can change zone temperature values
or the conveyor speed and adjust the outcome toward a perfect 10.0.
Target 10-OK features: