13) After the oven stabilizes, turn the M.O.L.E. Profiler on and press the record button.
The record button will need to be pressed even if the M.O.L.E. Profiler is
configured to start if the start parameters Trigger Temperature or Points
Delay are configured.
14) Pass the thermally protected M.O.L.E. Profiler and test assembly through the
machine.
It is highly recommended that protective gloves are used when retrieving the
thermal barrier from the oven and when opening the thermal barrier.
15) As the test assembly and M.O.L.E. Profiler emerge from the machine, carry the
test assembly with sensors attached and the M.O.L.E. Profiler in the Thermal
barrier to a table or flat surface.
If a sensor is removed before the M.O.L.E. Profiler has stopped collecting
data, the data for that channel might become distorted.
16) Open the Thermal barrier and if the Record LED is still flashing this means the
M.O.L.E. Profiler is still recording and it must be stopped.
17) Remove the M.O.L.E. Profiler from the Thermal barrier. Handle it carefully, as the
case may still be warm.
18) Disconnect the sensors from the M.O.L.E. Profiler and place it near the computer.
19) Press the OK button on the M.O.L.E. Profiler and wait for the GO or NO-GO
indication (RED or GREEN). By pressing the OK button, the M.O.L.E. Profiler