User's Manual Part 1

Button:
Action:
ON/OFF
Turns Profiler "ON/OFF".
Record
Starts/Stops Profiler recording data.
OK
Invokes "OK" process where the last
recorded profile is compared to
pre-configured criteria resulting in a "Pass"
or "Fail" mode.
Activity Indicators: These are LED's that indicate what state the SuperM.O.L.E.®
Gold 2 Profiler is in. Refer to the illustration and table below.
LED:
Action:
LED Color
ON/OFF
Indicates Profiler is
"ON" and idle
Green (Flashing)
Record
Indicates Profiler is
recording data
Green (Flashing)
OK
Indicates recorded
profile passes
pre-configured
criteria using the
Target 10-OK tab in
the software.
Green - Pass
(Solid)
Red - Fail (Solid)
Temp(eratur
e)
Indicates if the
internal temperature
is at or above a
certain threshold.
Red (Solid)
>40°C
Battery
Indicates when the
internal Power Pack
voltage is low
Red (Solid) <3.0V
RF (Radio
Frequency)
Indicates when unit
and RF receiver is
transferring data
Blue (Flashing)
Channel
Indicators
Indicates if the
channel is
configured and/or
the attached
thermocouple is a
complete circuit
Green -
Complete
Circuit (Solid)
Red - Configured
(Solid)
Rider
Indicates when
Profiler is connected
to a RIDER® NL 2
test pallet
Green (Solid)
Charge
Indicates when the
internal Power Pack
is charging
Yellow (Solid)