User's Manual Part 3
MEGAM.O.L.E.® Help System Guide ♦326♦
5.5.9.5. Align Profile Peaks
If sensors are placed along a line parallel to the direction of flow in a conveyorized
process so they enter and exit oven zones at different times, the resulting Data Plots lag
behind one another. The Align Profile Peaks command automatically aligns the Time
(X) axis maximum peak values for each Data Plot so the results can be easily compared
during analysis.
A conveyor speed must be set to properly use this command. Refer to topic
Software>Menus>Machine>Set Machine Information or Software>Page
Tabs>Profile>Data Graph>Conveyor Speed Indicator for more details.
To align profile peaks:
1) On the Profile menu, click Align Profile Peaks the channel lag values are
automatically calculated, and the Data Plots adjust to reflect them. A check mark
appears to the left of the command indicating the software is in Align Profile
Peaks mode. Repeat this step to disable the command.