User's Manual Part 3

MEGAM.O.L.E.® Help System Guide 292
3) Set the machine conveyor speed. The software uses this value to calculate the
Time (X) Scale values when Distance units are displayed. This number is also
used as the actual conveyor speed when prediction data lines are added. Refer
to topic Software>Menus>Tools>Prediction Tool for more information.
To properly display a machine model on the Data Graph, a conveyor speed
must be set. If you do not know what the conveyor speed is, the software
allows you to estimate it based on the machine information and the data run
profile. Refer to topic Software>Menus>Machine>Estimate Conveyor Speed
for more information.
4) Set the machine temperature units.
5) Set the Zone Temperatures in the zone matrix. These temperatures could be the
upper and lower thresholds of acceptable temperatures to meet process
standards or temperature settings of upper and lower heat sources. Upper zone
temperatures appear as solid lines and lower zones appear as dotted lines on
the Data Graph.