♦191♦ MEGAM.O.L.E.® Help System Guide
Save Target 10 Specs button: This button saves the currently displayed
settings to a Target 10 (.XMK) file. This file then can be used when setting a
process in the Fresh Start workflow wizard or using the Set Process command.
Read/Send I/O Pod buttons: These buttons read and send the Target 10-OK
settings to and from the MEGAM.O.L.E.® I/O Pod. When reading, the software
downloads the settings into the Target 10-OK tab for validation. When sending,
the software uploads the settings to the I/O Pod so the user can invoke the "OK"
process. This process is where the last recorded profile is compared to the OK
settings resulting in a "Pass" or "Fail" result. This is done without connecting the
MEGAM.O.L.E.® profiler to the computer by pressing the OK button on the Main
module.
OK command button: This button resets the Target 10-OK parameters back to
the original results that are permanently saved in the currently selected data run
(.XMG) file.