User's Manual Part 2

233 MEGAM.O.L.E.® Help System Guide
X-Axis Units
Time units and measurement type can be globally set for the X-Axis.
The user can select from the following scales:
Point: the data points collected from the Process-Origin.
Time-Relative: Time measured from the Process-Origin
Time-Absolute: Time of day
Distance: Distance from the Process Origin (Meters, Centimeters, Feet or
Inches).
Files
The user can decide how to set the default file name when saving a data run profile
(.XMG) and the default Data Table template they wish to use.
When saving a data run file, the software includes options to add the set Machine,
Assembly, Process and Computer Name.
Once the default filename is set, the (.XMG) file will be incremented
automatically to avoid that file from being overwritten.
If a user creates a new Data Table template, it can save using the template commands.
If the new template is to be used as the default, the new one can be specified in this text
box. The new template will now be loaded every time the program is started.
Profile
The user can display the Target 10 optional feature in the Data Table. Refer to topic
Software>Page Tabs>Profile>Target 10 for more information.
Show
The user can select the Auto align Peaks and select the amount of Y-Axis gridlines to
display on the Data Graph
When Auto align Peaks is selected, the software automatically aligns the Time (X) axis
maximum peak values for each Data Plot so the results can be easily compared during
analysis.
Colors
The software allows the user to change the background color of the Data Graph with
colors from the Windows default pallet.