Datasheet
EA uniTFT Vorläufig
Designation Command code Description
Define port macro #MHP Port, "Makroname"(delete old macro) Should the status of the I/O pins of the port
Port(0-15) be altered, the macro is acces-
sed "Macro Name". Should the command
be executed without a "Macro Name", the
current macro definition is deleted.
Define bit macro #MHB Bit, Edge, "Makroname"(delete old
macro)
Defines the macro "Macro Name” for the
port pin Pin(0-127) and the flank Edge (0=
Falling; 1= Increasing). Should the com-
mand be executed without a "Macro
Name", the current macro definition is dele-
ted.
Define analogue macro #MHA Channel, AnalogType, "Makroname"
(delete old macro)
Defines in the channel Channel(0-3) the
"Macro Name" macro The Type of the ana-
logue macro AnalogueType needs to be
taken into consideration in the process.
Should the command be executed without
a "Macro Name", the current macro defi-
nition is deleted.
Define RTC second macro #MDS , "Makroname" (delete old macro) Accesses the macro "Macro Name" every
second. Should the command be executed
without a "Macro Name", the current
macro definition is deleted.
Define operation end macro #MDA Object-id, "Makroname" (delete old
macro)
Defines an end macro in the object Object
ID. The "Macro Name" macro is only exe-
cuted once the operation of the object has
come to an end Object ID. Should the com-
mand be executed without a "Macro
Name", the current macro definition is dele-
ted.
Define touch macro #MDT Object-id/Group-id, "Makroname
down" (delete old macro); "Makroname
up" (Altes Makro löschen), "Makro-
name drag" (Altes Makro löschen)
Defines a touch function in the object
Object ID or in the object group Group ID.
In that respect, "Macro Name" macros are
specified for the pressed(down), unpres-
sed(up) and maintained(drag) states. The
corresponding object Object ID needs to
be defined for the latter as a touch objec-
t.Should the command be executed without
a "Macro Name", the current macro defi-
nition is deleted.
TYPES OF ANALOGUE MACROS
The hysteresis of the analogue channel set is observed. There is a description here of how to set the limits and
the hysteresis..
Technische Änderung vorbehalten.
Wir übernehmen keine Haftung für Druckfehler und Applikationsbeispiele..
Seite 76