Datasheet

EA DOGS102-6
Page 6
ELECTRONIC ASSEMBLY reserves
the right to change specifications
without prior notice. Printing and
typographical errors reserved.
INITIALISATION EXAMPLE
12:00 VIEWING ANGLE, TOP VIEW OPTION
If the display is read mostly from above (on the front of a laboratory power supply unit, for example), the preferred
angle of viewing can be set to 12 o’clock. This rotaties the display by 180°. A slightly different initialization setup is
required for this. Also keep in mind that the leftmost column (normally numbered as 0) will now change to 30.
*) Make sure that for 6:00 viewing direction SEG has to be set to „reverse“ (mirrored layout) !
Initialisation example (bottom view)
Command
CD D7 D6 D5 D4 D3 D2 D1 D0 Hex
Remark
(6) Set Scroll Line
0 0 1 0 0 0 0 0 0
$40 Display start line 0
(13) Set SEG direction
0 1 0 1 0 0 0 0 1
$A1 SEG reverse *)
(14) Set COM direction
0 1 1 0 0 0 0 0 0
$C0 Normal COM0~COM63
(10) Set All Pixel On
0 1 0 1 0 0 1 0 0
$A4 Disable -> Set All Pixel to ON
(11) Set Inverse Display
0 1 0 1 0 0 1 1 0
$A6 Display inverse off
(17) Set LCD Bias Ratio
0 1 0 1 0 0 0 1 0
$A2 Set Bias 1/9 (Duty 1/65)
(5) Set Power Control
0 0 0 1 0 1 1 1 1
$2F Booster, Regulator and Follower on
(8) Set VLCD Resistor Ratio
0 0 0 1 0 0 1 1 1
$27
Set Contrast
(9) Set Electronic Volume
0
1 0 0 0 0 0 0 1
$81
0 0 0 1 0 0 0 0
$10
(25) Set Adv. Program Control 0
0
1 1 1 1 1 0 1 0
$FA
Set Temperature compensation
curve to -0.11%C
1 0 0 1 0 0 0 0
$90
(12) Set Display Enable
0 1 0 1 0 1 1 1 1
$AF Display on
Initialisation example (changes for top view)
Command CD D7 D6 D5 D4 D3 D2 D1 D0 Hex Remark
(13) Set SEG direction
0 1 0 1 0 0 0 0 0
$A0 SEG normal
(14) Set COM direction
0 1 1 0 0 1 0 0 0
$C8 COM reverse COM63~COM0
Orientation for 12 o’clock
(Top View)
Orientation for 6 o’clock
(Bottom View)