Programming manual Selecta II Control T4290, T4530, T4650, T4900, T41200, T4300S, T4420S TD30, TD50, TD75, TD100, TD135, TD30x30, TD45x45 WD4130, WD4240 T4250 from machine no. 23350/0006970 T4350 from machine no. 23250/0003715 487 05 40 01/EN 2011.01.
Contents Contents Safety precautions......................................................................................5 Programming...............................................................................................7 Gas reset button.....................................................................................7 Operating panel......................................................................................8 Quick-diagram............................................................
Safety Precautions Safety Precautions Do not dry unwashed items in the machine The machine is not to be used if industrial chemicals have been used for cleaning. Do not allow minors to use the machine. Do not hose down the machine with water. The machine's door lock must under no circumstances be bypassed.
Programming Programming To enter the programming mode press service button A. 1 After pressing the service button A the display shows: 0 -- = Group 0. Program the dryer, see Service Manual for Selecta Control from ver. 4.xx for programming details. Gas reset button The button B is the gas reset button. 1 High voltage on the printed circuit board Note that there is high voltage on the circuit board. Never touch high voltage parts without first breaking the current at the main power switch. 1 .
Programming 8 Operating panel There are different types of operating panels. On the dryer operating panel the buttons might not have any symbols in which case they are only usable when the dryer is in service mode. In service mode the 4 buttons are used for changing the parameters. 2 Selected temperature Light emitting diode is lit at the selected temperature or show the defaulttemperature setting. Default temperature can be set in Group B in parameter A 05.
Programming 9 Quick-diagram Area A Main groups Subgroups Group 0 - Temperature / drying time 0 01 - 0 08 Group 1 - Reading total counters 1 01 - 1 05 Group 2 - Code to area B Area B Area B see service manual Selecta Control from ver. 4.
Programming 10 Changing of parameters in Group 0 1. SELECTA CO N TRO L Adjusting drying time 1. Press Enter. The display shows 0 01, indicating Group 0, parameter location 01 = High temperature. 2. Press Up to reach parameter location 0 06. This is the parameter location for the Time per coin or push value. The value in this location is the number of drying minutes that will be added when a coin is deposited (coin machines) or Up is pushed. 487 48709 2210 9300.00 40.00 2. SELECTA CO N TRO L 3.
Programming Adjusting operating temperatures 1. Press Enter. The display shows 0 01, indicating Group 0, parameter location 01 = High temperature. 11 1. SELECTA CO N TRO L 2. Press Enter again to enter this parameter location. The display shows _ 70 (°C). Note: The flashing bar at the bottom of the left digit indicates that this is a two-digit parameter. 487 48709 2210 9300.00 40.00 2. SELECTA CO N TRO L 3. Press Enter key to edit this parameter value. The “70” will begin to flash. 4.
Programming 12 Reading the hour counter in Group 1 1. SELECTA CO N TRO L Example: 1. Press Up. The display shows 1 _ _ indicating Group 1 = Reading total counters 2. Press Enter. The display now shows 1 01 indicating Group 1, parameter 01 = Permanent total hour counter. 487 22 93 40.00 2. SELECTA CO N TRO L 3. Press Enter again to enter this parameter location. The display shows - 00.
Programming 13 Parameter overview- Area A Group 0 - Setting temperatures and drying time Parameter Designation Step Range Factory setting Comments T4190, T4250, T4350, T4300S, T4300LE 0 01 High temperature 30 - 70°C 1°C 70 Air outlet temperature High 0 02 Medium temperature 30 - 70°C 1°C 60 Air outlet temperature Medium 0 03 Low temperature 30 - 70°C 1°C 50 Air outlet temperature Low T4290, T4530, T4650, T4900, T41200 0 01 High temperature 30 - 80°C 1°C 80 Ai
Programming 14 Error codes overview Error code Description E 01 Not in use E 02 Not in use E 03 The input sensor has short circuited The thermistor that measures air temperature at the drum inlet or the wires running to the sensor has short circuited. E 04 The output sensor has short circuited The thermistor that measures air temperature at the drum outlet or the wires running to the sensor has short circuited.
Programming Error codes overview Error code Description E 19 Not in use E 20 Machine is out of operation The tumble dryer has been deactivated by the PC software. E 21 Network error, no polling CMIS The computer has not called the tumble dryer during the timeout period. E 22 Network error, no polling CBT The computer has not called the tumble dryer during the timeout period. E 23 Not in use E 24 Condensate container is full The condensate container is full and the pump is not operating.
Electrolux Laundry Systems Sweden AB 341 80 Ljungby, Sweden www.electrolux.com/laundrysystems Share more of our thinking at www.electrolux.