User manual
13.2 Lamp
WARNING!
There is a risk of electrical shock.
The lamp and the lamp glass cov-
er can be hot.
Before you change the lamp:
• Deactivate the appliance.
• Remove the fuses from the fuse box or
deactivate the circuit breaker.
CAUTION!
Put a cloth on the bottom of the
interior of the appliance. It pre-
vents damage to the lamp glass
cover and the cavity.
Always use the same lamp type.
Replacing the lamp at the cavity
ceiling:
1.
Turn the lamp glass cover counter-
clockwise to remove it.
2.
Clean the glass cover.
3.
Replace the lamp with a suitable 300
°C heat-resistant lamp.
4.
Install the glass cover.
14. WHAT TO DO IF…
WARNING!
Refer to the Safety chapters.
Problem Possible cause Remedy
The appliance does
not heat up.
The appliance is deactiva-
ted.
Activate the appliance.
The appliance does
not heat up.
The clock is not set. Set the clock.
The appliance does
not heat up.
The necessary settings are
not set.
Check the settings.
The appliance does
not heat up.
The Child Lock is activated. Refer to "Activating and de-
activating the Child Lock
function".
The appliance does
not heat up.
The fuse is released. Make sure that the fuse is
the cause of the malfunc-
tion. If the fuse releases
again and again, contact a
qualified electrician.
The lamp does not
operate.
The lamp is defective. Replace the lamp.
If you cannot find a solution to the prob-
lem yourself, contact your dealer or the
service centre.
The necessary data for the service centre
is on the rating plate. The rating plate is
on the front frame of the appliance cavity.
We recommend that you write the data here:
Model (MOD.) .........................................
Product number (PNC) .........................................
Serial number (S.N.) .........................................
26