Datasheet
CTI – SOFTWARE DEVELOPMENT GROUP
© 2008 Electrolux Major Appliances Europe, All rights reserved
17
File: AMI technical Guide v1.pdf - Date: 04/02/2008
1 Target Device RxD (TxD Host)
2: Target Device TxD (RxD Host)
3: +5VDC (regulated)
4: GND
6-Way Cap – Female Contacts
(Tyco 172331-1 cap housing)
(Front View – Contacts Side)
1
4
56
2
3
1 Target Device RxD (TxD Host)
2: Target Device TxD (RxD Host)
3: not used
4: GND
5: not used
6: +5VDC (regulated)
1 Target Device RxD (TxD Host)
2: Target Device TxD (RxD Host)
3: +5VDC (regulated)
4: GND
6-Way Cap – Female Contacts
(Tyco 172331-1 cap housing)
(Front View – Contacts Side)
1
4
56
2
3
1
4
56
2
3
1 Target Device RxD (TxD Host)
2: Target Device TxD (RxD Host)
3: not used
4: GND
5: not used
6: +5VDC (regulated)
Fig. 22. RAST5 DAAS Cable – 6-Way Plug










