4.3. Appliance Cable Wirings
The current section provides the wiring diagrams of the appliance cables that you can use with
the AMI.
1 Target Device RxD (TxD Host)
2: Target Device TxD (RxD Host)
3: +5VDC (regulated)
4: GND
EDGE RAST2.5 - 4 way
(Lumberg 3521 04)
(Front View – Contacts Side)
6-Way Cap – Female Contacts
(Tyco 172331-1 cap housing)
(Front View – Contacts Side)
1
4
56
2
3
1 Target Device RxD (TxD Host)
2: Target Device TxD (RxD Host)
3: not used
4: GND
5: not used
6: +5VDC (regulated)
1 Target Device RxD (TxD Host)
2: Target Device TxD (RxD Host)
3: +5VDC (regulated)
4: GND
EDGE RAST2.5 - 4 way
(Lumberg 3521 04)
(Front View – Contacts Side)
6-Way Cap – Female Contacts
(Tyco 172331-1 cap housing)
(Front View – Contacts Side)
1
4
56
2
3
1
4
56
2
3
1 Target Device RxD (TxD Host)
2: Target Device TxD (RxD Host)
3: not used
4: GND
5: not used
6: +5VDC (regulated)
Fig. 21. RAST2.5 DAAS Cable – 6-Way Plug