Datasheet

CTI – SOFTWARE DEVELOPMENT GROUP
© 2008 Electrolux Major Appliances Europe, All rights reserved
13
File: AMI technical Guide v1.pdf - Date: 04/02/2008
4. APPLIANCE CABLES
You need an Appliance Cable to complete the connection to the target board. The appliance cable
connects the Target Cable Connector to the electronic board:
Electrolux
APPLIANCE BOARD
Target Cable
Connector
Module
Connector
Board
Connector
Appliance Mini Interface v3 Appliance Cable
Electrolux
APPLIANCE BOARDAPPLIANCE BOARD
Target Cable
Connector
Module
Connector
Board
Connector
Appliance Mini Interface v3 Appliance Cable
Fig. 15. AMI, Appliance Cable, and Board
The ends of the Appliance Cable are the Module Connector and the Board Connector.
The Module Connector matches the Target Cable Connector, while the Board Connector plugs into
the Appliance Board.
4.1. Module Connector Pin Assignments
The following figure provides the pin assignments for the standard 6-Way plug AMI variant
(Tyco cap housing):
1 Target Device RxD (TxD Host)
2: Target Device TxD (RxD Host)
3: MACS Cable Select
4: GND
5: MACS Signal (single-ended)
6: +5VDC (regulated)
6-Way Cap – Female Contacts
(Tyco 172331-1 cap housing)
(Front View – Contacts Side)
1
4
56
2
3
1 Target Device RxD (TxD Host)
2: Target Device TxD (RxD Host)
3: MACS Cable Select
4: GND
5: MACS Signal (single-ended)
6: +5VDC (regulated)
6-Way Cap – Female Contacts
(Tyco 172331-1 cap housing)
(Front View – Contacts Side)
1
4
56
2
3
6-Way Cap – Female Contacts
(Tyco 172331-1 cap housing)
(Front View – Contacts Side)
1
4
56
2
3
1
4
56
2
3
Fig. 16. Tyco 172331-1 Module Connector Pin Assignment