Installation guide

14 www.electrolux.com
Wrap the piping, drain hose and
connecting cable from the down to up.
Secure the wrapped piping along the
exterior wall using saddle or equivalent.
Fig.3.4.3-1
3. In cases where the outdoor unit is
installed above the indoor unit level:
Wrap the piping and connecting cable
from the down to up.
Form a trap to prevent water from
entering the room.
Secure the wrapped piping along the
exterior wall using saddle or equivalent.
Fig.3.4.3-2
3.4.4 Checking the Drainage
1. Open and lift the indoor unit front panel.
Hold the lower part of the left and right
sides of the panel, pull it against you
and lift it stops with support.
Fig.3.4.4-1
2. Check the drainage
Carefully pour a glass of water on the
evaporator.
Ensure the water ows through the
drain hose of the indoor unit without
any leakage and goes out the drain exit.
Fig.3.4.4-2
3. Dain piping
The drain hose should point downward
for easy drain ow.
Seal small openings
around piping with
a gum type sealer
Seal small openings
around piping with
a gum type sealer
Trap
Trap
Drain hose
Drain hose
Trap is required to prevent water
from entering into electrical parts
Wrapping
Pipe
Drain
hose
Connection
cable
Drain hose