Electroswitch • 180 King Avenue • Weymouth, MA 02188 • TEL: (781) 335-5200 • FAX: (781) 335-4253 • www.electroswitch.com
51
ELECTROSWITCH
TYPE WL LOCK-OUT RELAY
The Type WL Lock-Out Relay product line was also acquired from Westinghouse in 1988.
Countless Type WLs are still providing reliable protection in older facilities decades after they
were first installed. Electroswitch is pleased to announce that we can provide replacement
units for most of the WLs still in service. Please contact us with the WL part number of the
switch you are replacing and we will be happy to respond with an approval drawing or a
suggested replacement if your WL cannot be duplicated.
2
3
4
5
6
8
10
2
3
4
5
6
8
10
3
4
5
6
8
10
4
5
6
8
10
5
6
8
10
6
8
10
422D949G01
422D949G02
422D949G03
422D949G04
422D949G05
422D949G06
422D949G07
422D949G15
422D949G16
422D949G17
422D949G18
422D949G19
422D949G20
422D949G21
422D949G22
422D949G23
422D949G24
422D949G25
422D949G26
422D949G27
422D949G28
422D949G29
422D949G30
422D949G31
422D949G32
422D949G33
422D949G34
422D949G35
422D949G36
422D949G37
422D949G38
422D949G39
422D950G01
422D950G02
422D950G03
422D950G04
422D950G05
422D950G06
422D950G07
422D950G15
422D950G16
422D950G17
422D950G18
422D950G19
422D950G20
422D950G21
422D950G22
422D950G23
422D950G24
422D950G25
422D950G26
422D950G27
422D950G28
422D950G29
422D950G30
422D950G31
422D950G32
422D950G33
422D950G34
422D950G35
422D950G36
422D950G37
422D950G38
422D950G39
422D949G08
422D949G09
422D949G10
422D949G11
422D949G12
422D949G13
422D949G14
422D949G41
422D949G42
422D949G43
422D949G44
422D949G45
422D949G46
422D949G47
422D949G48
422D949G49
422D949G50
422D949G51
422D949G52
422D949G53
422D949G54
422D949G55
422D949G56
422D949G57
422D949G58
422D949G59
422D949G60
422D949G61
422D949G62
422D949G63
422D949G64
422D949G65
422D950G08
422D950G09
422D950G10
422D950G11
422D950G12
422D950G13
422D950G14
422D950G41
422D950G42
422D950G43
422D950G44
422D950G45
422D950G46
422D950G47
422D950G48
422D950G49
422D950G50
422D950G51
422D950G52
422D950G53
422D950G54
422D950G55
422D950G56
422D950G57
422D950G58
422D950G59
422D950G60
422D950G61
422D950G62
422D950G63
422D950G64
422D950G65
Coil 1-2
1
3-4 5-6 7-8 9-10 11-12 13-14 15-16 17-18 19-20
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Non-Trip
by Handle
Trip by
Handle
Non-Trip
by Handle
Trip by
Handle
Modern Handle Heavy-Duty Handle
No. of
Stages
Style Numbers Without Coils
Rotor Contacts
A = Contact Open in Reset. Closed in Trip Position. N.O. B = Contact Closed in Reset. Open in Trip Position. N.C.
1 On 250 volts dc control circuits this contact must be connected in series with coil contact.
TABLE I: WL SWITCH STYLES (less coils)
A
B
C
D
E
F
G
H
I
J
K
701B500G01
701B501G01
701B502G01
701B503G01
701B504G01
701B505G01
701B506G01
701B507G01
701B508G01
701B509G01
701B510G01
.73
2.68
4.05
6.2
8.6
12.2
18.5
28.0
45.5
59.0
104.0
8.7
17.1
21.4
27.0
31.0
33.0
44.0
54.0
70.0
84.0
111.0
6.2
21.0
30.0
43.0
52.0
97.0
140.0
208.0
50
95
115
135
155
200
243
297
*16
19 16
16
*17
18
*16
16
*17
19 13
14
14
16
*17
19
14
15
*16
17
Coil
Code
Coil Style
Number
Ohms
Resistance
Minimum Trip
DC Volts
Ohms
impedance
(not tripped)
Minimum Trip
AC Volts
Direct Current Alternating Current - 60 Cycles
Control Voltage-DC
Time in Milliseconds
Control Voltage-AC
Time in Milliseconds
24 48 125 250
110 220
TABLE II: COIL OPERATING CHARACTERISTICS
Coil part numbers must be specified at the time of order. Those marked with an asterisk (*) are considered
to be standard for the operating voltage indicated. These coils should not be used for 5 ampere series
trip operation from secondary of current transformers, as the burden is too great. Time is in milliseconds.
Time may vary slightly for AC tripping, depending on point of AC cycles at which the coil is energized.