User manual
abrasive cleaning pads, solvents or
metal objects.
• If you use an oven spray, follow the
safety instruction on it's packaging.
• Do not clean the catalytic enamel (if
applicable) with any kind of
detergent.
2.6 Internal lighting
WARNING!
Risk of electric shock.
• The type of light bulb or halogen
lamp used for this appliance is for
household appliances only. Do not
use it for house lighting.
• Before replacing the lamp, disconnect
the appliance from the power supply.
• Only use lamps with the same
specifications.
2.7 Service
• To repair the appliance contact the
Authorised Service Centre.
• Use original spare parts only.
2.8 Disposal
WARNING!
Risk of injury or suffocation.
• Contact your municipal authority for
information on how to discard the
appliance correctly.
• Disconnect the appliance from the
mains supply.
• Cut off the mains electrical cable
close to the appliance and dispose of
it.
• Flat the external gas pipes.
3. INSTALLATION
WARNING!
Refer to Safety chapters.
3.1 Gas connection
The gas supply ramp is on the back of
the oven.
Do not use rubber flexible pipes.
1. Before the gas connection,
disconnect the oven from the mains.
2. Close the primary valve of the gas
supply.
3. Do not fully put the oven into the
built-in cabinet, leave approximately
30 cm gap.
4. Connect gas supply.
A B C
A. Gas supply ramp, end of shaft
with ramp
B. Washer
C. Elbow
5. Put the supplied gasket between the
pipe and the gas supply ramp. Turn
the pipe to the 1/2" gas supply ramp.
6. Use a 22 mm spanner to tighten the
nuts. Keep the gas supply ramp in
the correct position. Gently handle
the gas supply circuit.
WARNING!
Do not use flame to check
for leaks.
7. Fully move the oven into the built-in
cabinet.
WARNING!
Do not squeeze the gas
supply ramp and the pipe
when you move the oven
into the built-in cabinet.
8.
Seal the connection correctly. Use a
leak detection to control it.
3.2 Adjustment to different
types of gas
Only a qualified technician is authorized
to handle adjustment of different types
of gas.
The oven is set for different types of gas,
you can switch between liquid gas and
natural gas with the correct injectors.
ENGLISH
7