User manual

accessories. Before you use the oven for
the first time, put the bottom plate with
the hole on its front part in the burner
area, as shown in "Product description"
chapter.
5.2 Initial Cleaning
Remove all accessories and removable
shelf supports from the oven.
Refer to "Care and cleaning" chapter.
Clean the oven and the accessories
before the first use.
Put the accessories and the removable
shelf supports back to their initial
position.
5.3 Preheating
Preheat the empty appliance before first
use.
1. Set the maximum temperature.
2. Let the appliance operate for 1 hour.
3. Set the function
.
4. Let the appliance operate for 15
minutes.
Accessories can become hotter than
usual. The appliance can emit an odour
and smoke. This is normal. Make sure
that the airflow is sufficient.
Let the oven cool down. Dampen a soft
cloth with warm water and a little mild
washing-up liquid and use this to clean
the oven cavity.
6. DAILY USE
WARNING!
Refer to Safety chapters.
6.1 Ignition of oven gas burner
Oven safety device:
The gas oven has a
thermocouple. It stops the
gas flow if the flame goes
out.
1. Press the knob for the gas control
and turn it to .
2. Keep the knob for the gas control
pushed for 15 seconds or less to let
the thermocouple warm up. Do not
release the knob until the flame
ignites, otherwise the gas flow is
interrupted.
Do not keep the knob for the gas control
pushed for more than 15 seconds. If the
oven burner does not ignite after 15
seconds, release the knob for the gas
control, turn it into off position, open the
oven door. Wait minimum 1 minute,
close the oven door and try to ignite the
oven burner again.
6.2 After igniting the oven gas
burner
1. Release the knob for the gas control.
2. Turn the knob for the gas control to
set the temperature.
Control the flame through the holes in
the cavity bottom plate.
The power indicator turns on when you
turn the knob for the oven functions.
6.3 Knob for the gas control
Symbol Function
Conventional Cooking
Heat from the bottom of the oven. Range of temperature adjust-
ment (150 °C - 250 °C).
www.aeg.com12