Technical data

wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 8x0.00/04/13 v5
Version 1.51
EMP8x0.00/04/13 v5 subject to technical modification page 29/42
Example:
programmed value
of the accepted
coin
transferred data, binary data,
hexadecimal
Chan. 1 20.00 1100 000 1101 0000 1110 0000 1111 0010 1000 0001 C0 D0 E0 F2 80
Chan 2 05.00 1100 0000 1101 0000 1110 0101 1111 0000 1000 0010 C0 D0 E5 F0 81
Chan 3 00.50 1100 0000 1101 0101 1110 0000 1111 0000 1000 0011 C0 D5 E0 F0 82
Chan 4 00.25 1100 0101 1101 0010 1110 0000 1111 0000 1000 0100 C5 D2 E0 F0 83
Chan 17 00.05 1100 0101 1101 0000 1110 0000 1111 0000 0111 0001 C5 D0 E0 F0 70
Figure 11 Data format for acceptance of coins with different coin values and
different channels
Figure 12 Timing diagram for the first 3 data bytes