Cooktop OPERATING INSTRUCTIONS Model EHT 9780 K 35689-9702 AM
For your safety This new appliance is easy to use, however, make sure to read this handbook before installing and using it for the first time. In this way you can obtain best use, avoid incorrect operations, use the appliance in complete safety and respect the environment.. Installation • Appliance installation and connection to the power supply must only be carried out by QUALIFIED PERSONNEL. Before carrying out any operation, make sure the appliance is DISCONNECTED from the power supply.
Contents For the installer For the user For your safety Operating instructions Cleaning and maintenance Periodical maintenance Assistance and spare parts Warranty terms 2 3 4 5 5 5 This appliance complies with the following EEC Directives: -73/23 and 90/683 (Low Voltage); -89/336 (Electromagnetic Compatibility); -90/396 (Gas Appliances) -93/68 (General Standards) and subsequent amendments.
For correct use of the rings To ensure lower gas consumption and better efficiency, only use flat bottom recipients of suitable size for the rings, as given in the table at the foot of the page. Also, as soon as a liquid starts to boil, lower the flame enough to keep it on the boil. Burner min diameter max diameter Triple crown Medium (semirapid) Small (auxiliary) 160 mm. 120 mm. 80 mm. 260 mm. 220 mm. 160 mm.
Periodical maintenance Have the state and efficiency of the gas pipe and the pressure regulator (if present) periodically checked. If any anomalies are detected, have the faulty part replaced (and not repaired). To guarantee correct operation and safety, periodically grease the gas adjustment cocks. · Periodical lubrication of the cocks must only be carried out by QUALIFIED PERSONNEL; contact only qualified personnel in case of anomalies in appliance operation.
Technical specifications Power supply Gas burner power Triple crown burner 3.8 kW Semirapid burner (medium) 1.9 kW Auxiliary burner (small) 1.0 kW Appliance class 3 Dimensions of opening for fitting II2H3+ Width 830 mm. Natural gas G20 / 20 mbar Depth 480 mm. Category Appliance setting 230 V 50 Hz Gas inlet connection G 1/2" Instructions for the installer IMPORTANT: This appliance can only be installed and used in permanently ventilated places in conformity with UNI 7129 and UNI 7131.
If the opening cannot be made in the room where the appliance is installed, the necessary air can come from an adjacent room, provided: • it is not a bedroom or a dangerous environment; • it is not in depression; • the ventilation between the room where the appliance is installed and the adjacent room is ensured by means of permanent openings (UNI-CIG 7129). Fume exhaust Gas cooking appliances must exhaust the fumes through hoods directly connected to flues or directly to the outside (Fig. 5).
Electrical connection The appliance is arranged to operate on a 230 V singlephase power supply. Connection must be made in compliance with current standards and regulations. Before carrying out the connection, make sure: 1) the limiter valve and the electrical system can take the appliance load (refer to the serial no.
Conversion to other types of gas Replacing nozzles 1. Remove the grates. 2. Remove the burner caps and flame spreaders. 3. Using a 7 mm socket wrench, unscrew and remove (Fig. 10) the nozzles, replacing them with those required for the type of gas used (refer to the table on this page). 4. Refit the parts by carrying out the above operations in reverse order. 5. Then replace the rating plate (located near the gas connection) with that corresponding to the new type of gas.
Fitting on modular cabinets SR SR TC SR A 51 88 0 0 Fig. 12 Dimensions in mm A = Auxiliary burner SR = Semirapid burner TC = Triple crown burner These tops are designed for fitting on modular kitchen cabinets having a depth of between 550 and 600 mm and appropriate characteristics. The side walls of the cabinets on which the cooktop is installed must not be higher than the worktop. Side walls higher than the top must be at least 150 mm from the opening in the top.
FITTING POSSIBILITIES (Dimensions in mm) On base cabinet with door Adequate arrangements must be provided for in the construction of the cabinet to prevent possible contact with the overheated housing of the top during operation. A possible solution for avoiding this problem is illustrated in fig. 17. The panel under the top must be easily removed to allow securing and release of the top in case of technical assistance intervention.
Grafiche MDM - Forlì 01/06