instruction booklet GB gas hob EHG 75932
electrolux
electrolux 3 Welcome to the world of Electrolux Thank you for choosing a first class product from Electrolux, which hopefully will provide you with lots of pleasure in the future. The Electrolux ambition is to offer a wide variety of quality products that make your life more comfortable. You find some examples on the cover in this manual. Please take a few minutes to study this manual so that you can take advantage of the benefits of your new machine.
electrolux Contents Instructions for the User Important safety information.............................................................................. 5 Description of the hob ...................................................................................... 7 Operation ......................................................................................................... 8 Maintenance and Cleaning .............................................................................
electrolux 5 Important safety information You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 950950. Installation This appliance must be installed and serviced by a competent person as stated in the Gas Safety (Installation and Use) Regulations Current Editions and the IEE Wiring Regulations. For appliances installed in the Republic of Ireland please refer to NSAIDomestic Gas Installations I.S.
electrolux When using the hob for a long period time, the ventilation should be improved, by opening a window or increasing the extractor speed. Do not use this hob if it is in contact with water. Do not operate the hob with wet hands. Ensure the control knobs are in the ‘OFF’ position when not in use. When using other electrical appliances, ensure the cable does not come into contact with the hot surfaces of the cooking appliance.
electrolux 7 Description of the hob 2 4 2 3 1 5 1. 2. 3. 4. 5. Rapid Burner Semi-rapid Burner Auxiliary Burner Dual Burner Control knobs INSTALLATION Any gas installation must be carried out by a registered competent person, and in accordance with existing rules and regulations. The relevant instructions are to be found in the second section of this manual. Please, ensure that, once the hob is installed, it is easily accessible for the engineer in the event of a breakdown.
electrolux Operation Hob burners control knobs The symbols on the knobs mean that : there is no gas supply there is maximum gas supply there is minimum gas supply Lighting the burners For easier lighting, proceed before putting a pan on the pan support. Rapid, Semi rapid and Auxiliary burners To light a burner: push in the relevant control knob and turn it anticlockwise to maximum position ( ). Dual burner The dual burner consist of two crowns that can be lighted simultaneously or separately.
electrolux 9 After lighting the flame, keep the knob pushed down for about 5 seconds. This will allow the "thermocouple" (Fig. 2 - lett. D) to be heated and the safety device to be switched off, otherwise the gas supply would be interrupted. Then adjust the flame as required. If the burner does not ignite, turn the control knob to off position, and try again. When switching on the mains, after installation or a power cut, it is quite normal for the spark generator to be activated automatically.
electrolux Using the hob correctly To ensure maximum burner efficiency, it is strongly recommended that you use only pots and pans with a flat bottom fitting the size of the burner used, so that flame will not spread beyond the bottom of the vessel (see the table below).
electrolux 11 Maintenance and Cleaning Before any maintenance or cleaning can be carried out, you must DISCONNECT the hob from the electricity supply. The hob is best cleaned whilst it is still warm, as spillage can be removed more easily than if it is left to cool. This appliance cannot be cleaned with steam or with a steam cleaning machine. The Hob Top Regularly wipe over the hob top using a soft cloth well wrung out in warm water to which a little wasing up liquid has been added.
electrolux The Burners The burner caps and crowns can be removed for cleaning. Wash the burners caps and crowns using hot soapy water, and remove marks with a mild paste cleaner. A well moistened soap impregnated steel wool pad can be used with caution, if the marks are particularly difficult to remove. After cleaning, be sure to wipe dry with a soft cloth. The Ignition electrode The electric ignition is obtained through a ceramic electrode which contains a metal electrode (Page 9 - Fig. 2 - C).
electrolux 13 Something not working? If the hob is not working correctly, please carry out the following checks before contacting your local Service Force Centre. symptom solution There is no spark when lighting the gas. Check that the unit is plugged in and the electrical supply is switched on. Check that the RCCB has not tripped (if fitted). Check the mains fuse has not blown. Check the burner cap and crown have been replaced correctly, e.g. after cleaning. The gas ring burns unevenly.
electrolux Instructions for the Installer Engineer technical data OVERALL dimensions Width: Depth: 744 mm 510 mm CUT OUT dimensions Width: Depth: 560 mm 480 mm SUPPLY CONNECTIONS Gas: R 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V~ 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse HEAT INPUT Auxiliary Burner 1.0 kW (3413 BTU/HR) Semirapid Burner 2.0 kW (6826 BTU/HR) Rapid Burner 3.0 kW (10239 BTU/HR) Dual Burner 5.
electrolux 15 BURNER TYPE NOMINAL NOMINAL THERMAL REDUCED POWER POWER kW kW NOMINAL FLOW RATE NATURAL GAS LPG 20 mbar 28-30/37 mbar Nozzles reference 100/mm m3/h Nozzles reference 100/mm g/h G30 G31 Auxiliary burner 1,0 0,33 70 0,095 50 73 71 Semi-rapid burner 2,0 0,45 96 0,190 71 145 143 Natural gas: 3,0 L.P.G.: 2,8 0,75 119 0,286 86 204 200 Natural gas: 5,0 L.P.G.
electrolux Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S. 813 Current Editions and the ETCI Rules for Electrical Installations. Provision for Ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S.
electrolux 17 For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S 813 Current Edition Section 7- Permitted Locations of Appliance. Installation IMPORTANT Any gas installation must be carried out by a GAS SAFE REGISTER installer. Please, ensure that, once the hob is installed, it is easily accessible for the engineer in the event of a breakdown.
electrolux Building In Building over a cupboard or drawer If the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface. It is also recommended to carry out the electrical connection to the hob as shown in diagrams 1 and 2.
electrolux 19 Fitting the hob into the worktop Carry out the building in of the hob as follows: 1. place the seals supplied with the hob on the front edge of the cut out. Then, place them at 86 mm from the side edges and at 10 mm from the rear edge, as shown in Fig.3, taking care that the seals meet without overlapping. 2. Place the hob in the cut out, taking care that it is centred. 3. Fix the hob with the relevant fixing clamps, supplied with the injectors kit (see Fig.4).
electrolux Electrical connections Any electrical work required to install this hob should be carried out by a qualified electrician or competent person, in accordance with the current regulations. THIS HOB MUST BE EARTHED. The manufacturer declines any liability should these safety measures not be observed. This hob is designed to be connected to a 230 V 50 Hz AC electrical supply. Before switching on, make sure the electricity supply voltage is the same as that indicated on the hob rating plate.
electrolux 21 The replacement of electric cable must be carried out exclusively by the service force centre or by personnel with similar competencies, in accordance with the current regulations.
electrolux Wiring diagram
electrolux 23 Fault finding Preliminary Electrical Systems Check Blue Brown START Isolate appliance and carry out: A: Earth Continuity check. YES NO Green Yellow Blue Green Yellow Brown Carry out: C: Polarity check. Carry out: D: Resistance to Earth check. Has inlet fuse blown? Electricity supply should now be satisfactory. YES NO PLUG (with cover removed) Earth Wire Green/Yellow Neutral Wire Blue SOCKET (face view) ( ) E( ) FUSE Inlet wiring faulty. Rectify any fault.
electrolux A. EARTH CONTINUITY CHECK Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary. — Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 W (Ohm), check all earth wires for continuity and all contacts clean and tight. B. INSULATION CHECK Appliance electrically disconnected, all switches ON. a) meter set on W (Ohms) x 1 scale. Test leads from L to N in appliance terminal block.
electrolux 25 Ignition System / Gas Ignition Ignitor does not spark YES Check gas supply at burner NO Check plug top fuse and replace if necessary Check polarity and earth continuity of supply point Check earth continuity of appliance Check continuity from 'N' on the mains connector block and "O" on the ignitor unit Check continuity from 'L' on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Light burner manually Check by
electrolux Commissioning When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below. 1. Turn the gas tap to the MAX position and ignite. 2. Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below. Procedure: 1. Re-ignite the burner and set to MIN. 2. Remove the control knob. 3.
electrolux 27 Conversion from natural gas to LPG IMPORTANT The replacement/conversion from natural gas to LPG should only be undertaken by a competent person. It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. The gas rate is adjusted to suit. Method 1. Ensure that the gas taps are in the 'OFF' position 2. Isolate the hob from the electricity supply 3.
electrolux
electrolux 29
electrolux
electrolux 31
www.electrolux.co.uk 39712-3402 04/09 R.