EHG30200K .................................................. ...............................................
www.electrolux.com CONTENTS SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 DAILY USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 HELPFUL HINTS AND TIPS . . . . . . . . . . . . . . . . . . . . . .
ENGLISH 3 SAFETY INFORMATION This appliance is suitable for the following markets: IE GB Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use causes injuries and damages. Always keep the instructions with the appliance for future reference. CHILDREN AND VULNERABLE PEOPLE SAFETY WARNING! Risk of suffocation, injury or permanent disability.
www.electrolux.com Gas connection • All gas connections should be made by a qualified person. • Make sure that there is air circulation around the appliance. • The information about the gas supply is on the rating plate. • This appliance is not connected to a device, which evacuates the products of combustion. Make sure to connect the appliance according to current installation regulations. Pay attention to requirements regarding adequate ventilation.
ENGLISH • Clean the appliance with a moist soft cloth. Only use neutral detergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects. DISPOSAL WARNING! Risk of injury or suffocation. • Contact your municipal authority for information on how to discard the appliance correctly. • Disconnect the appliance from the mains supply. • Cut off the mains cable and discard it. • Flat the external gas pipes.
www.electrolux.
ENGLISH 7 DAILY USE WARNING! Refer to "Safety information" chapter. IGNITION OF THE BURNER WARNING! Be very careful when you use open fire in kitchen environment. Manufacturer decline any responsibility in case misuse of the flame Always light the burner before you put cookware. To light the burner: 1. Turn the control knob counterclockwise to the maximum position ( ) and push it down. 2. Keep the control knob pushed for approximately 5 seconds; this will let thermocouple to warm up.
www.electrolux.com HELPFUL HINTS AND TIPS WARNING! Refer to "Safety information" chapter. ENERGY SAVINGS • If possible, always put the lids on the pans. • When the liquid starts to boil, turn down the flame to barely simmer the liquid. Use cookware with diameters applicable to the size of burners. Burner Diameters of cookware Rapid 160 - 240 mm Auxiliary 80 - 160 mm WARNING! Do not use cast iron pans, potstones, grill or toaster plates on gas burners.
ENGLISH 9 CARE AND CLEANING WARNING! Refer to "Safety information" chapter. WARNING! Deactivate the appliance and let it cool down before you clean it. Disconnect the appliance from the electrical supply before you do cleaning or maintenance work. Scratches or dark stains on the surface have no effect on how the appliance operates. • You can remove the pan supports to easily clean the hob.
www.electrolux.com TROUBLESHOOTING Problem There is no spark when lighting the gas Possible cause Remedy • There is no electrical supply • Make sure that the unit is connected and the electrical supply is switched on. • Control the fuse. If the fuse is released more than one time, refer to a qualified electrician. • Burner cap and crown are placed uneven • Make sure that the burner cap and crown are in correct positions.
ENGLISH 1 2 3 MOD. MOD. PROD.NO. PROD.NO. SER.NO SER.NO 03 IT DATA DATA MADE IN ITALY MODEL 0049 MODEL 1 Stick it on Guarantee Card and send this part 2 Stick it on Guarantee Card and keep this part 3 Stick it on instruction booklet MOD. PROD.NO. SER.NO.
www.electrolux.com INSTALLATION WARNING! Refer to "Safety information" chapter. WARNING! The following instructions about installation, connection and maintenance must be carried out by qualified personnel in compliance with standards and local regulations in force. IMPORTANT SAFETY REQUIREMENTS This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).
ENGLISH When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. Make sure that the main connection pipe does not exert any strain on the hob. If you use flexible metal pipes make sure that they agree to ISO 10380 and ISO 10807 standards. Be careful they do not come in touch with mobile parts or they are not squeezed. Also be careful when the hob is put together with an oven. 2. 3. 4. 13 Turn the knob on the minimum position.
www.electrolux.com WARNING! Make sure that the cut off plug is disposed of safely. A cut off plug put into a 13 amp socket is a safety hazard. There is a risk of electrical shock. contact opening width of minimum 3 mm. • You must have the correct isolation devices: line protecting cut-outs, fuses (screw type fuses removed from the holder), earth leakage trips and contactors. • The connection cable parts must not be heated to a temperature above 90°C.
ENGLISH 15 30 mm A min 20 mm (max 150 mm) A 60 mm B A — supplied seal A) Removable panel B) Space for connections Kitchen unit with oven The hob recess dimensions must obey the indication and the kitchen unit must be equipped with vents to let a continuous supply of air. The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit.
www.electrolux.com By-pass diameters Burner Ø By-pass in 1/100 mm. Auxiliary 28 Burner Ø By-pass in 1/100 mm. Rapid 42 Gas burners RENORDUCED MAL POWPOWER ER NORMAL POWER NATURAL GAS G20 (2H) 20 mbar BURNER kW Auxiliary Rapid kW inj. 1/100 mm m³/h LPG (Butane/Propane) G30/G31 (3+) 28-30/37 mbar inj. 1/100 mm G30 G31 28– 37 30 mba mbar r g/h g/h 1.0 0.33 70 0.095 50 73 71 2.9 (natural gas) 2.7 (LPG) 0.75 119 0.
ENGLISH 17
www.electrolux.
ENGLISH 19
www.electrolux.