EGG6343NOR EGG6343NOX EGG6343NOW EGG6343NDX ................................................ .............................................
www.electrolux.com CONTENTS 1. 2. 3. 4. 5. 6. 7. 8. 9. SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 DAILY USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ENGLISH 3 1. SAFETY INFORMATION Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use causes injuries and damages. Always keep the instructions with the appliance for future reference. 1.1 Children and vulnerable people safety WARNING! Risk of suffocation, injury or permanent disability.
www.electrolux.com • Never try to extinguish a fire with water, but switch off the appliance and then cover flame e.g. with a lid or a fire blanket. • Do not store items on the cooking surfaces. • Do not use a steam cleaner to clean the appliance. • Metallic objects such as knives, forks, spoons and lids should not be placed on the hob surface since they can get hot. 2. SAFETY INSTRUCTIONS This appliance is suitable for the following markets: IT 2.
ENGLISH 5 nect the appliance from the mains at all poles. The isolation device must have a contact opening width of minimum 3 mm. • Use only correct isolation devices: line protecting cut-outs, fuses (screw type fuses removed from the holder), earth leakage trips and contactors. • Used oil, that can contain food remnants, can cause fire at a lower temperature than oil used for the first time. • Do not put flammable products or items that are wet with flammable products in, near or on the appliance.
www.electrolux.com • Do not clean the burners in the dishwasher. • Clean the appliance with a moist soft cloth. Only use neutral detergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects. • Contact your municipal authority for information on how to discard the appliance correctly. • Disconnect the appliance from the mains supply. • Cut off the mains cable and discard it. • Flat the external gas pipes. 2.4 Disposal WARNING! Risk of injury or suffocation. 3.
ENGLISH Always light the burner before you put cookware. To light the burner: Push the control knob down and turn it counterclockwise to the maximum position ( ). 2. Keep the control knob pushed for approximately 5 seconds; this will let thermocouple to warm up. If not, the gas supply will be interrupted. 3. Adjust the flame after it is regular. 1. If after some tries the burner does not light, check if the crown and its cap are in correct positions.
www.electrolux.com • When the liquid starts to boil, turn down the flame to barely simmer the liquid. Use cookware with diameters applicable to the size of burners. Burner Diameters of cookware Triple Crown 180 - 260 mm Front Semirapid 120 - 180 mm Rear Semirapid 120 - 220 mm Auxiliary 80 - 180 mm WARNING! Make sure that pot handles is not above the front edge of the cooktop. Make sure that pots are centrally put on the rings in order to get maximum stability and to get lower gas consumption.
ENGLISH 9 special cleaner applicable for surface of hob. 2. Clean the appliance with a damp cloth and some detergent. 3. At the end rub the appliance dry with a clean cloth. The stainless steel can become tarnished if it is too much heated. Refer to this you must not cook with potstones, earthenware pans or cast iron plates. • Be very careful when you replace the pan supports to prevent the hob top from damage. After cleaning, dry the appliance with a soft cloth. Removing the dirt: 1.
www.electrolux.com If there is a fault, first try to find a solution to the problem yourself. If you cannot find a solution to the problem yourself, speak your dealer or the local Service Force Centre. • Product number (PNC) ................. • Serial Number (S.N.) ................. Use the original spare parts only. They are available at Service Force Centre and approved spare parts shops.
ENGLISH WARNING! The following instructions about installation, maintenance and ventilation must be carried out by qualified personnel in compliance with the regulation in force (UNICIG 7129 - 7131). Make sure that the kitchen is well ventilated: keep natural ventilation holes open (at least 100 cm²) or install a mechanical extractor hood. 8.1 Gas Connection Choose fixed connections or use a flexible pipe in stainless steel in compliance with the regulation in force.
www.electrolux.com • If you change from natural gas G20 20 mbar to liquid gas, fully tighten the bypass screw in. • If you change from liquid gas to natural gas G20 20 mbar, undo the by-pass screw approximately 1/4 of a turn (1/2 of a turn for Triple Crown burner). WARNING! Make sure the flame does not go out when you quickly turn the knob from the maximum position to the minimum position. 8.5 Replacement of the connection cable To replace the connection cable use only H05V2V2-F T90 or equivalent type.
ENGLISH If you install the hob under a hood, please see the installation instructions of the hood for the minimum distance between the appliances. 8.7 Possibilities for insertion Kitchen unit with door Kitchen unit with oven The hob recess dimensions must obey the indication and the kitchen unit must be equipped with vents to let a continuous supply of air. The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit.
www.electrolux.com Gas supply: G20 (2H) 20 mbar Appliance class: 3 By-pass diameters Burner Ø By-pass in 1/100 mm Burner Ø By-pass in 1/100 mm Auxiliary 28 Triple Crown 56 Semi-rapid 32 Gas burners for NATURAL GAS G20 20 mbar BURNER NORMAL POWER kW inj. 1/100 mm Auxiliary 1.0 70 Semi-rapid 2.0 96 Triple Crown 4.0 146 Gas burners for LPG (Butane / Propane) G30 28-30 mbar G31 37 mbar g/h g/h NORMAL POWER kW inj. 1/100 mm Auxiliary 1.0 50 73 71 Semi-rapid 2.
ENGLISH 15
892953069-D-362012 www.electrolux.