www.electrolux.com CONTENTS 1. 2. 3. 4. 5. 6. 7. 8. 9. SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 DAILY USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 HELPFUL HINTS AND TIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ENGLISH 1. 3 SAFETY INFORMATION This appliance is suitable for the following markets: GB Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use causes injuries and damages. Always keep the instructions with the appliance for future reference. 1.1 Children and vulnerable people safety WARNING! Risk of suffocation, injury or permanent disability.
www.electrolux.com nect the appliance from the mains at all poles. The isolation device must have a contact opening width of minimum 3 mm. • Use only correct isolation devices: line protecting cut-outs, fuses (screw type fuses removed from the holder), earth leakage trips and contractors. Gas connection • All gas connections should be made by a qualified person. • Make sure that there is air circulation around the appliance. • The information about the gas supply is on the rating plate.
ENGLISH 1.4 Care and Cleaning 5 1.5 Disposal WARNING! Risk of damage to the appliance. WARNING! Risk of injury or suffocation. • Clean regularly the appliance to prevent the deterioration of the surface material. • Do not use water spray and steam to clean the appliance. • Clean the appliance with a moist soft cloth. Only use neutral detergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects.
www.electrolux.com Always light the burner before you put cookware on it. To light the burner: 1. Push and hold the spark generator button . 2. At the same time turn the knob counterclockwise to the maximum position and push it down to light the burner. 3. Release the spark generator button when the burner lights but keep the knob on this position for approximately 5 seconds; this will let the thermocouple warm up. If not, the gas supply will be interrupted. 4. Adjust the flame after it is regular.
ENGLISH WARNING! Do not put the same pan on two burners. 7 Do not place unstable or deformed pots on the rings to prevent from spill and injury. Information on acrylamides WARNING! Make sure pot handles do not protrude over the front edge of the cooktop and that pots are centrally positioned on the rings in order to achieve maximum stability and to obtain lower gas consumption.
www.electrolux.com 5.1 Cleaning of the spark plug 5.2 Periodic maintenance This feature is obtained through a ceramic ignition candle with a metal electrode. Keep these components well clean to prevent difficult lighting and check that the burner crown holes are not obstructed. Periodically speak your local Service Force Centre to check the conditions of the gas supply pipe and the pressure adjuster, if fitted. 6.
ENGLISH 1 2 3 MOD. MOD. PROD.NO. PROD.NO. SER.NO SER.NO 03 IT DATA DATA MADE IN ITALY MODEL 9 MOD. PROD.NO. SER.NO. 0049 TYPE 230V-50Hz IP20 MODEL 1 Stick it on Guarantee Card and send this part 2 Stick it on Guarantee Card and keep this part 3 Stick it on instruction booklet 7. INSTALLATION WARNING! Refer to "Safety information" chapter.
www.electrolux.com Location The hob may be located in a kitchen, a kitchen/diner or bed sitting room (with a volume greater than 20 m³), but not in a bathroom or shower room. The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm. If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob. For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.
ENGLISH 2. 3. 4. Turn the knob on the minimum position. Remove the knob. With a thin screwdriver, adjust the bypass screw position. A 11 contact opening width of minimum 3 mm. • You must have the correct isolation devices: line protecting cut-outs, fuses (screw type fuses removed from the holder), earth leakage trips and contactors. • The connection cable parts must not be heated to a temperature above 90°C.
www.electrolux.com Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in accordance with the following code: Green and yellow - Earth Blue - Neutral Brown - Live 1. Connect the green and yellow (earth) wire to the terminal in the plug which is marked with the letter 'E' or the earth symbol , or coloured green and yellow. 2. Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter 'N' or coloured black. 3.
ENGLISH Kitchen unit with oven The hob recess dimensions must obey the indication and the kitchen unit must be equipped with vents to let a continuous supply of air. The electrical connection of the hob and the oven must be in- 13 stalled separately for safety reasons and to let easy remove oven from the unit. 50 cm2 120 cm2 360 cm2 180 cm2 8.
www.electrolux.com Gas burners NORMAL POWER BURNER kW REDUCED POWER kW NORMAL POWER NATURAL GAS G20 (2H) 20 mbar LPG (Butane/Propane) G30/ G31 (3+) 28-30/37 mbar inj. 1/100 mm m³/h inj. 1/100 mm G30 28–30 mbar G31 37 mbar g/h g/h Auxiliary 1.0 0.33 70 0.095 50 73 71 Semirapid 2.0 0.45 96 0.190 71 145 143 Rapid 3.0 (natural gas) 2.8 (LPG) 0.75 119 0.286 86 204 200 9. ENVIRONMENT CONCERNS Recycle the materials with the symbol .