Basic Guide
Machine settings
Setting Implementation
Buzzer permanent
on/off
The alarm is by default always off. To set permanent alarm on (off):
1. Turn the programme selector to any programme.
2. Press simultaneously the Dryness and Long anti-crease buttons and hold
down for approx. 5 seconds.
Water hardness
1)
1. Turn the programme selector to any programme.
2. Press simultaneously the Long anti-crease and Start/Pause buttons and
hold down for approx. 5 seconds.
3. Press the Start/Pause button until you set desired level:
- low conductivity <300 μS/cm
- medium conductivity 300-600 μS/cm
- high conductivity >600 μS/cm
4. To memorize setting press simultaneously the Long anti-crease and
Start/Pause buttons or turn knob to
off position
1) Water contains, a variable quantity of limestone and mineral salts of which quantities vary according
to geographical locations thus varying its conductivity values. Relevant variations of the conductivity
of the water compared to those prefixed by the factory could slightly influence the residual humidity
of the laundry at the end of the cycle. Your dryer allows you to regulate the sensitivity of the drying
sensor based on conductivity values of the water.
14 electrolux