User manual

16 www.electrolux.com
Occurrence Possible Cause Solution
Dehumidier is
operating, but
room is not dry
enough.
Humidity setting is
too high.
Select Dehum function, and adjust
in manual mode to a lower setting or
choose Continunous operation for
maximum dryness.
Dehumidier has
been installed or
restarted recently.
The higher the moisture in the room air,
the longer it takes for the room air to
become dry.
Dehumidier does
not have sufcient
clearance to
operate.
Air ow to air intake is blocked. See “4.1
Selecting a Location”.
Room temperature
is too low.
Unit will not operate satisfactorily if the
room temperature is below 5°C (41°F).
See “4.2 How it Works”.
Refer to causes under "The programme / cycle lasts too long.".
Frost appears on
coils above water
tank.
Dehumidier has
been turned on
recently.
This is normal due to refrigerant rushing
through the coil. Frost will usually
disappear within 60minutes.
Abnormal noise.
Room Temperature
is too low.
Please operate dehumidier when room
temperature is above 5°C (41°F).
The oor is not at.
Please install the dehumidier on level
oor.
"dF" code shows
on the display,
the compressor
stop running and
the dehumidier
works at MAX fan
speed.
Room Temperature
is low, the
dehumidier enters
in Defrost function
automatically.
This is normal, the dehumidier will
automatically quit Defrost function after
some minutes and continue working with
current operating setting.