User manual

27 electrolux operation
operation electrolux 28
ENG
ENG
Operation
When using the unit
• When first using the dehumidifier, operate the unit continuously 24 hours.
• This unit is designed to operate with a working environment between
5°C/41°F and 35°C/95°F.
• If the unit has been switched off and needs to be switched on again quickly,
allow approximately three minutes for the correct operation to resume.
• Do not connect the dehumidifier to a multiple socket outlet, which is also
being used for other electrical appliances.
• Select a suitable location, making sure you have easy access to an
electrical outlet.
• Plug the unit into a suitable electrical socket-outlet with earth connection.
• Make sure the Water bucket is correctly fitted otherwise the unit will not
operate properly.
Setting the Timer
• When the unit is on, first press the Timer button, the Timer Off indicator light
illuminates. It indicates the Auto Stop program is initiated. Press it again the
Time On indecator light illuminates.It indicates the Auto Start is initiated.
• When the unit is off, first press the Timer button, the TIMER ON indicator
light illuminates. It indicates the Auto Start program is initiated. Press it
again the Time Off indecator light illuminates.It indicates the Auto Stop is
initiated.
• Press or hold the UP or DOWN pad to change the Auto time by 0.5 hour
increments, up to 10 hours, then at 1 hour increments up to 24 hours. The
control will count down the time remaining until start.
• The selected time will register in 5 seconds and the system will
automatically revert back to display the previous humidity setting.
• When the Auto start & Auto stop times are set, within the same program
sequence, TIMER ON OFF indicator lights illuminate identifying both ON
and OFF times are now programmed.
• Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0
will cancel the Auto Start/Stop function.
• When LED display window displays the code of P2, the Auto Start/Stop
function will also be cancelled.
Dryer mode (optional)
The unit can make the MAX
dehumidification function when it is
under the Dryer mode. The fan speed
is fixed at high fan speed. The
humidity level is automatically
controlled according to the actual
room humidity.The unit will quit dryer
mode after a maximum 10 hours'
operation.
The Dryer mode must be operated in a
close room,do not open the door and
window.
To make the best effective
dehumidification ,please first
dehydrate the wet clothes.
Make sure to direct airflow at the wet
clothes.
For thick and heavy wet clothes may
not get the best effective
dehumidification.
Do not cover the air outlet of the unit
with clothes. It may cause excessive
heat, fire or failure of unit.
Do not place the wet clothes on the
top of the unit and do not make the
water drop into the unit. It may cause
electric shock,creepage or failure of
unit.
W
et clothes
Allow 30-50cm of distance
on the top and right sides
of the unit to the wet
clothes
30-50 cm
Airflow
30-50 cm