ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY
INSTRUCTIONS
Be sure your cooktop is installed and grounded
properly by a qualified installer or service
technician.
•These cooktops must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No.
70—latest edition in the United States, or with
CSA Standard C22.1, Canadian Electrical Code,
Part 1, in Canada.
WARNING
The electrical power to the cooktop
must be shut off while line connections are being
made. Failure to do so could result in serious injury
or death.
Provide Electrical Connection
Install the junction box under the cabinet and run
120/240or120/208Volt,ACwirefromthemain
circuitpanel.NOTE:DONOTconnectthewiretothe
circuitpanelatthistime.Waituntilallwireshavebeen
connected in the junction box.
Electrical Requirements
Observe all governing codes and local ordinances.
1. A3-wireor4-wiresinglephase120/240or120/208
Volt,60HzAConlyelectricalsupplyisrequiredona
separatecircuitfusedonbothsidesoftheline(time-
delayfuseorcircuitbreakerisrecommended,40Aor
50A).DONOTfuseneutral.
NOTE:Wiresizesandconnectionsmustconformwith
thefusesizeandratingoftheapplianceinaccordance
withtheNationalElectricalCodeANSI/NFPANo.70–
latestedition,orwithCSAstandardC22.1,Canadian
ElectricalCode,Part1,andlocallocalcodesand
ordinances.
WARNING
An extension cord must not be used
with this appliance. Such use may result in a fire,
electrical shock, or other personal injury.
2. The appliance should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. Theexible
armored cable extending from this appliance should
beconnecteddirectlytothegroundedjunctionbox.
The junction box should be located as shown in
Figure3withasmuchslackaspossibleremainingin
thecablebetweentheboxandtheappliance,soit
canbemovedifservicingisevernecessary.
3. Asuitablestrainreliefmustbeprovidedtoattach
the flexible armored cable to the junction box.
Unpacking Instructions
1. Unpackandvisuallyinspectthecooktop
2. Be sure the bottle of cleaner conditioner packed
in the literature bag is left where the user can
nditeasily.Itisimportantthattheceramic-glass
smoothtop be pretreated before use see Cooktop
Cleaning and Maintenance section in the Use and
Care Guide.
Model and Serial Number Location
The serial plate is located under the cooktop.
Whenorderingpartsforormakinginquiresaboutyour
cooktop,alwaysbesuretoincludethemodelandserial
numbers and a lot number or letter from the serial plate
onyourcooktop.
Electrical connection
Itistheresponsibilityandobligationoftheconsumerto
contactaqualiedinstallertoassurethattheelectrical
installationisadequateandisinconformancewiththe
NationalElectricalCodeANSI/NFPANo.70-latestedition,
orwithCSAStandardC22.1,CanadianElectricalCode,
Part1,andlocalcodesandordinances.
Risk of electrical shock (Failure to
heed this warning may result in electrocution or
other serious injury.) This appliance is equipped
with copper lead wire. If connection is made to
aluminum house wiring, use only connectors that
are approved for joining copper and aluminum wire
in accordance with the National Electrical Code
and local code and ordinances. When installing
connectors having screws which bear directly on
the steel and/or aluminum flexible conduit, do no
tighten screws sufficiently to damage theexible
conduit. Do not over bend or excessively distort
flexible conduit to avoid separation of convolutions
en exposure of internal wires.
DONOTgroundtoagassupplypipe.DONOTconnect
toelectricalpowersupplyuntilapplianceispermanently
grounded.Connectthegroundwirebeforeturningon
the power.
Serial Plate
Location