Installation Guide
1
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
All dimensions are in inches (cm).
Allow 2" (5 cm) space below the armoured cable opening to clear the electric cable and
allow space for installation of the junction box on the wall at the back of the cooktop.
IMPORTANT INSTALLATION INFORMATION
•Allelectriccooktopsrunoffasinglephase,three-wireorfour-wirecable,240/208volt,60hertz,AConlyelec-
tricalsupplywithground.
•Minimumdistancebetweencooktopandoverheadcabinetryis30"(76.2cm).
Figure 1
P/N318201413(0901)Rev.H
English–pages1-5
Español–pages6-10
Français-pages11-16
A
B
C
E
F
G
H***
D
CooktopDimensions
*30"(76.2cm)min.for
unprotected cabinet
24"(61cm)min.for
protected surface
CooktopCutoutDimensions
30"Min.*
(76.2cm)
For Standard Installation:
351/8"
(89.2cm)
1" (2.5 cm)
4"X8"(10.2cmx20.3cm)
opening to route armoured cable.
7¼"
(18.4cm)
**Note: D & E are critical to the proper installation
of the cooktop. Please make sure to respect those
dimensions. D reflects a finished dimension it is
recommended to undercut this dimension and
adjust upon installation of the appliance due to
thevariationincountertopmaterials.
Do not slide unit into cabinet cutout.
Protruding screws on the bottom of
unit may damage the bottom front
finish.
Model
Product dimensions cutout dimensions
H. height below
cooktop***
A. width B. depth c. height width depth
d** e** F G
36 (91.4) 35
7
/
8
(91.1) 25¾ (65.4) 7¾ (19.7) 35
15
/
16
(91.3) 35
3
/
16
(89.4) 22 (55.9) 1
1
/
8
(2.9) Max. 7½ (19.1)
INSTALLATION AND SERVICE MUST BE PERFORMED
BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING
FOR YOUR SAFETY: Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
Canada United States










