Service manual

54
Failure code chart
Failure code Fault condition Action
E4A The drying time has exceeded program Press Pause Cancel and SELECT buttons for
time for cycle. 6 seconds to exit test modes. Position cycle
selector to NORMAL, temperature selector to
HIGH HEAT and touch START. Check for any
thing that would extend dry times such as: no
heat, restricted vent, blower fan blade broken
or loose, dryer installed in closet with solid door,
or bad connection in moisture sensor bar cir
cuit or dirty bars. If dryer operates normally but
code returns, replace electronic control.
E 5B No heat. Refer to flow chart dryer does not heat.
E 68 One of the keys (buttons) is Enter function test mode and perform key
stuck closed (active). (button) test to determine which button is at
fault. Carefully free the and perform the test
again. If button is free but the key struck code
still exists, replace electronic control.
E 8C High limit thermostat has trip to many times Check for blocked lint filter, blocked exhaust,
in a certain amount of time. air leaks around air duct, broken blower fan
blades, worn or loose drum seals, dryer installed
in closet with solid doors or door seal not
correctly seated.
E AF Microcontroller has been reset Clear code, exit mode and start dryer. If
by Watchdog timer. problem persists, replace electronic control.