Service manual
32
0" (0 cm)
1" (2.54 cm)
4. A minimum of 120 square inches (774.2 square cm)
of opening, equally divided at the top and bottom of
the door, is required. Air openings are required to
be unobstructed when a door is installed. A louvered
door with equivalent air openings for the full length of
the door is acceptable.
MINIMUM INSTALLATION CLEARANCES (Inches)
SIDES REAR TOP FRONT
Alcove 0 (0 cm) 0 (0 cm) 15 (38.1 cm)
Closet 0 (0 cm) 0 (0 cm) 15 (38.1 cm) 1 (2.54 cm)
Closet door ventilation required: 2 louvered openings each
60 square inches (387 square centimeters) — 3 inches
(7.6 cm) from bottom and top of door.
NOTE: Under counter and stack models - 0 inches
(0 cm) for sides, rear, and top.
THIS DRYER MUST BE EXHAUSTED OUTDOORS.
5. The following illustrations show minimum clearance
dimensions for proper operation in a recess or closet
installation.
CLOSET DOOR
60 SQ. IN.
(387.1 SQ.
60 SQ. IN.
(387.1 SQ. CM)
0" (0 cm)
0" (0 cm)