Service manual

8
Resistance
Electrical component @ 77F (25C)
Dispenser valve soleniods 800 ± 7%
Door lock solenoid 1325 ± 10%
Pump motor 12 ± 7%
NTC Thermistor dispenser 3K
NTC Thermistor heater 4.8K
Water heater 14 ± 10%
M1 TO M2 5.3 ± 7%
M2 TO M3 5.3 ± 7%
M1 TO M3 5.3 ± 7%
M4 TO M5 118 ± 7%
QUICK REFERENCE SHEET
Component resistance chart.
Water fill height 3.5 ± .5 “
No load, start position of permanent press cycle.
Electrical requirements.
Incoming water pressure.
Drain requirements.
Motor.
Water usages
Per fill
Per cycle
Based on 1 wash and 3 rinse fills
Circuit - Individual, properly polarized and grounded 15
amp. branch circuit fused with 15 amp. time delay fuse
or circuit breaker.
30 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.)
Drain capable of eliminating 17 gals (64.3 L) per minute.
A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
The standpipe height above the floor should be:
Minimum height: 24 in. (61 cm)
Maximum height: 96 in. (244 cm)
Motor
No load agitate wattage - Max 150
No load spin wattage - Max 550
4.23 gallons
16.92 gallons