Wiring diagram

3
Diagnostic Mode
Selector Test/Activated Component Operator Check LCD row LCD digits
Position Electric Gas
NOTE : To clear the error code (s): Press and hold the far left key under the display and “cancel” buttons
simultaneously for 3 seconds.
6. To exit Diagnostic Mode:
a) Unplug the power cord, wait 5-8 seconds, then reconnect the power cord OR
b) Turn the program knob to the Start Position (lights/Buttons Test). Press the “cancel” and far left button under the
display simultaneously for 6 seconds.
0
1
2
3
4
5
6
7
8
9
10
Lights / Buttons test
Motor Clockwise (CW)
Contact Sensor
Motor Clockwise (CW)
Lights / Buttons
test + Motor CW
Motor CW + Heater
1
Motor CW + Heater
1 + Heater 2
Motor CW + Heater
1 + Heater 2 +
Heater 3
Lights / Buttons
test + Motor CW +
igniter
Motor CW +
Heater
Motor CW +
Heater
Motor CW +
Heater
Motor CW
Error code history display
Software version
Check Motor function. Look for Drum
rotation in clockwise direction
Check moisture reading. Place fingers
across Contact Sensor and look for digit
display to change from “1111” to “8888”
Check Motor function. Look for Drum
rotation in clockwise direction
Check all buttons and lights. Press all
buttons and check for beep and button
ID number in digit display. Check to see
that all Lights function
Check Motor and Heater function. Check
Outlet Control Thermistor value in digit
display.
Check Motor and Heater function. Check
Inlet Control Thermistor value in digit
display.
Check Motor and Heater function. Check
Outlet Control Thermistor value in digit
display.
Check for Mist
Check last 5 error codes displayed (See
Table above for error code definitions)
Software version
“MOTOR CW”
“MOIST. BARS”
“MOTOR CW”
“HEAT1 - NTC1”
“HEAT2 - NTC2”
“HEAT3 - NTC1”
“MIST VALVE”
Software
version
“1111” if Contact Sensor
open circuit;”8888" if
Contact Sensor short
circuited
button id number
Outlet Control Thermistor
value (degrees F)
Inlet Control Thermistor
value (degrees F)
Outlet Control Thermistor
value (degrees F)
error code
Software version