Oven User Manual
air-o-steam
class B
Natural Gas Combi Oven 102
air-o-steam
class B Natural Gas Combi Oven 102
The company reserves the right to make modifications to the products
without prior notice. All information correct at time of printing.
2012.07 .24
Front
Top
CWI=Cold Water inlet
D=Drain
DO=Overflow drain pipe
EI=Electrical connection
G=Gas connection
Side
Electric
Supply voltage:
268703(AOS102GBG2)230 V/1N ph/50/60 Hz
Circuit breaker required
Gas
ISO 7/1 gas connection diameter:1/2" MNPT
Natural gas:
Pressure:7" w.c. (17.4 mbar)
Steam generator:25 kW
Heating elements:92043 BTU (27 kW)
Total thermal load:153405 BTU (45 kW)
Water:
Water inlet "CW" connection:3/4"
Water inlet "FCW" connection:3/4"
Total hardness:5-50 ppm
Pressure:1.5-4.5 bar
Pressure:22-36 psi (1.5-4.5 bar)
Drain "D":1"1/4
Electrolux recommends the use of treated water, based on
testing of specific water conditions.
Please refer to user manual for detailed water quality
information.
Installation:
Clearance:5 cm rear and right hand sides.
Suggested clearance for service
access:50 cm left hand side.
Capacity:
GN:10 - 2/1 Gastronorm
GN:20 - 1/1 containers
Max load capacity:80 kg
Key Information:
External dimensions, Height:1058 mm
External dimensions, Width:1208 mm
External dimensions, Depth:1065 mm
Net weight:203 kg
Shipping weight:229 kg
Shipping volume:1.36 m³