User Guide

air-o-steam
class B
Natural Gas Combi Oven 202
air-o-steam
class B Natural Gas Combi Oven 202
The company reserves the right to make modifications to the products
without prior notice. All information correct at time of printing.
2012.07 .24
Front
Top
CWI=Cold Water inlet
D=Drain
DO=Overflow drain pipe
EI=Electrical connection
G=Gas connection
Side
Electric
Supply voltage:
268705(AOS202GBG2)230 V/1N ph/50/60 Hz
Circuit breaker required
Gas
ISO 7/1 gas connection diameter:1" MNPT
Natural gas:
Pressure:7" w.c. (17.4 mbar)
Steam generator:55 kW
Heating elements:187495 BTU (55 kW)
Total thermal load:323855 BTU (95 kW)
Water:
Water inlet "CW" connection:3/4"
Water inlet "FCW" connection:3/4"
Total hardness:5-50 ppm
Pressure:1.5-4.5 bar
Pressure:22-36 psi (1.5-4.5 bar)
Drain "D":2"
Electrolux recommends the use of treated water, based on
testing of specific water conditions.
Please refer to user manual for detailed water quality
information.
Installation:
Clearance:
Clearance: 5 cm rear and right
hand sides.
Suggested clearance for service
access:50 cm left hand side.
Capacity:
GN:20 - 2/1 Gastronorm
GN:40 - 1/1 containers
Max load capacity:200 kg
Key Information:
Net weight:414 kg
Shipping weight:444 kg
Shipping height:1795 mm
Shipping width:1243 mm
Shipping depth:1107 mm
Shipping volume:2.47 m³