EGG 9363 ................................................ .............................................
www.electrolux.com CONTENTS 1. 2. 3. 4. 5. 6. 7. 8. 9. SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 DAILY USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 HELPFUL HINTS AND TIPS . . . . . . . . . . . . . . . . . . . . . . . . . .
ENGLISH 1. 3 SAFETY INFORMATION This appliance is suitable for the following markets: GB Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use causes injuries and damages. Always keep the instructions with the appliance for future reference. 1.1 Children and vulnerable people safety WARNING! Risk of suffocation, injury or permanent disability.
www.electrolux.com nect the appliance from the mains at all poles. The isolation device must have a contact opening width of minimum 3 mm. • Use only correct isolation devices: line protecting cut-outs, fuses (screw type fuses removed from the holder), earth leakage trips and contractors. Gas connection • All gas connections should be made by a qualified person. • Make sure that there is air circulation around the appliance. • The information about the gas supply is on the rating plate.
ENGLISH 1.4 Care and Cleaning 5 1.5 Disposal WARNING! Risk of damage to the appliance. • Clean regularly the appliance to prevent the deterioration of the surface material. • Do not use water spray and steam to clean the appliance. • Clean the appliance with a moist soft cloth. Only use neutral detergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects. WARNING! Risk of injury or suffocation.
www.electrolux.com Always light the burner before you put cookware. To light the burner: Turn the control knob counterclockwise to the maximum position ( ) and push it down. 2. Keep the control knob pushed for approximately 5 seconds; this will let thermocouple to warm up. If not, the gas supply will be interrupted. 3. Adjust the flame after it is regular. 1. If after some tries the burner does not light, check if the crown and its cap are in correct positions.
ENGLISH • When the liquid starts to boil, turn down the flame to barely simmer the liquid. Use cookware with diameters applicable to the size of burners. Burner Diameters of cookware Triple Crown 180 - 260 mm Rapid 160 - 260 mm Semi-rapid 120 - 220 mm Auxiliary 80 - 180 mm WARNING! Do not put the same pan on two burners.
www.electrolux.com The stainless steel can become tarnished if it is too much heated. Refer to this you must not cook with potstones, earthenware pans or cast iron plates. Do not use aluminium foil to prevent damage the top during operation. Removing the dirt: 1. – Remove immediately: melting plastic, plastic foil, and food containing sugar. – Stop the appliance and let it cool down before you clean: limescale rings, water rings, fat stains, shiny metallic discolorations.
ENGLISH These data are necessary to help you quickly and correctly. These data are available on the supplied rating plate. • Model description ................. • Product number (PNC) ................. • Serial Number (S.N.) ................. Use the original spare parts only. They are available at Service Force Centre and approved spare parts shops. 1 6.1 Labels supplied with the accessories bag Stick the adhesive labels as indicated below: 2 3 MOD. MOD. PROD.NO. PROD.NO. SER.NO SER.
www.electrolux.com of 100 cm² is required. If it is installed in a room of volume between 5 m³ and 10 m³ an air vent of effective area of 50 cm² is required, while if the volume exceeds 11 m³ no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m³ and 11 m³. If there are other fuel burning appliances in the same room, B.S.
ENGLISH 11 of gas you use (see table in "Technical Information" chapter). 4. Assemble the parts, follow the same procedure backwards. 5. Replace the rating plate (it is near the gas supply pipe) with the one for the new type of gas supply. You can find this plate in the package supplied with the appliance. If the supply gas pressure is changeable or different from the necessary pressure, you must fit an applicable pressure adjuster on the gas supply pipe.
www.electrolux.com A The current regulations let only a qualified electrician or a competent person to replace the mains cable. Do not try to replace it if you are not qualified to do that. B 7.
ENGLISH 7.8 Possibilities for insertion Kitchen unit with door The panel installed below the hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary. 13 Kitchen unit with oven The hob recess dimensions must obey the indication and the kitchen unit must be equipped with vents to let a continuous supply of air. The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit.
www.electrolux.com By-pass diameters Burner Ø By-pass in 1/100 mm Burner Ø By-pass in 1/100 mm Rapid 42 Auxiliary 28 Triple Crown 56 Semi-rapid 32 Gas burners NORMAL POWER BURNER REDUCED POWER NORMAL POWER NATURAL GAS G20 (2H) 20 mbar LPG (Butane/Propane) G30/G31 (3+) 28-30/37 mbar m³/h inj. 1/100 mm G30 28–30 mbar G31 37 mbar kW kW inj. 1/100 mm g/h g/h Auxiliary 1.0 0.33 70 0.095 50 73 71 Semirapid 2.0 0.45 96 0.190 71 145 143 Rapid 2.8 0.75 115 0.
ENGLISH 15
356993602-A-172012 www.electrolux.