Directions for Use
Surfaces must be clean, dry and free from grease, dust and contaminants; Electrolube offer a range of cleaning
products, including Ultrasolve (ULS), for such applications. Ensure that all solvents have completely evaporated
prior to application.
RCS is a moisture curing system. Relative humidity of 50% or above is preferred for curing. Apply a thin layer
of product onto each bonding surface; the thickness of the layer will affect the rate of initial cure – the higher the
thickness applied, the longer it will take to reach the required strength. Final strength is obtained after ~24hours.
Bulk Packaging Specifications
Package Size
Diameter (mm)
Height (mm)
310 ml cartridge
45.9 (inside)
215.5 (without threaded nipple)
17 kg tin
285 (internal)
280 (internal)
Revision 6: January 2018