6.3. Methods and material for containment and cleaning up
Methods for cleaning up Wear protective clothing as described in Section 8 of this safety data sheet. Clear up spills
immediately and dispose of waste safely. Eliminate all ignition sources if safe to do so. No
smoking, sparks, flames or other sources of ignition near spillage. Do not allow material to
enter confined spaces, due to the risk of explosion. Absorb small quantities with paper towels
and evaporate in a safe place. Once evaporation is complete, place paper in a suitable waste
disposal container and seal securely. Flush contaminated area with plenty of water. Wash
thoroughly after dealing with a spillage. For waste disposal, see Section 13.
6.4. Reference to other sections
Reference to other sections For personal protection, see Section 8. See Section 11 for additional information on health
hazards. See Section 12 for additional information on ecological hazards. For waste disposal,
see Section 13.
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Usage precautions Keep out of the reach of children. Read and follow manufacturer's recommendations. Wear
protective clothing as described in Section 8 of this safety data sheet. Keep away from food,
drink and animal feeding stuffs. Handle all packages and containers carefully to minimise
spills. Keep container tightly sealed when not in use. Avoid the formation of mists. The
product is flammable. Keep away from heat, hot surfaces, sparks, open flames and other
ignition sources. No smoking. Do not handle until all safety precautions have been read and
understood. Do not handle broken packages without protective equipment. Do not reuse
empty containers.
Advice on general
occupational hygiene
Wash promptly if skin becomes contaminated. Take off contaminated clothing. Wash
contaminated clothing before reuse.
7.2. Conditions for safe storage, including any incompatibilities
Storage precautions Store locked up. Keep away from oxidising materials, heat and flames. Keep only in the
original container. Keep container tightly closed, in a cool, well ventilated place. Keep
containers upright. Protect containers from damage.
Storage class Flammable liquid storage.
7.3. Specific end use(s)
Specific end use(s) The identified uses for this product are detailed in Section 1.2.
SECTION 8: Exposure Controls/personal protection
8.1. Control parameters
Occupational exposure limits
Propan-2-ol
Long-term exposure limit (8-hour TWA): WEL 400 ppm 999 mg/m³
Short-term exposure limit (15-minute): WEL 500 ppm 1250 mg/m³
WEL = Workplace Exposure Limit
8.2. Exposure controls
Protective equipment
5/