Safety data sheet
ELECTRONIC CLEANING SOLVENT PLUS (COMBI)
WEL = Workplace Exposure Limit.
PENTANE (CAS: 109-66-0)
DNEL
Industry Dermal Long Term Systemic Effects 432 mg/kg/day
Industry Inhalation. Long Term Systemic Effects 3000 mg/m3
Consumer Oral Long Term Systemic Effects 214 mg/kg/day
Consumer Dermal Long Term Systemic Effects 214 mg/kg/day
Consumer Inhalation. Long Term Systemic Effects 643 mg/m3
PNEC
Water 0.23 mg/l
Sediment 1.2 mg/kg
Soil 0.55 mg/kg
STP 3.6 mg/l
PROPAN-2-OL (CAS: 67-63-0)
DNEL
Industry Dermal 888 mg/kg/day
Industry Inhalation. 500 mg/m3
Consumer Dermal 319 mg/kg/day
Consumer Inhalation. 89 mg/m3
Consumer Oral 26 mg/kg/day
PNEC
Freshwater 140.9 mg/l
Marinewater 140.9 mg/l
Sediment 552 mg/kg
Soil 28 mg/kg
8.2. Exposure controls
Process conditions
Use engineering controls to reduce air contamination to permissible exposure level. Provide eyewash station.
Engineering measures
Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit
is not exceeded.
Respiratory equipment
If ventilation is insufficient, suitable respiratory protection must be provided. It is recommended to use respiratory
equipment with combination filter, type A2/Р2. EN14387
Hand protection
Protective gloves must be used if there is a risk of direct contact or splash. The most suitable glove must be chosen in
consultation with the gloves supplier, who can inform about the breakthrough time of the glove material. Gloves of nitrile
rubber, PVA or Viton are recommended. Gloves should conform to EN374
Eye protection
Wear approved chemical safety goggles where eye exposure is reasonably probable. EN166
Other Protection
Wear appropriate clothing to prevent any possibility of liquid contact and repeated or prolonged vapour contact.
Hygiene measures
Wash hands at the end of each work shift and before eating, smoking and using the toilet. Use appropriate skin cream to
prevent drying of skin. When using do not eat, drink or smoke. DO NOT SMOKE IN WORK AREA!
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
9.1. Information on basic physical and chemical properties
Appearance
Aerosol. Liquid
Colour
Colourless.
Odour
Characteristic.
Solubility
Immiscible with water
Initial boiling point and boiling range
(°C)
36 (96.8 F)
Melting point (°C)
-130 (-202 F)
Relative density
0.650 @ 20 °c (68 F)
Bulk Density
650 kg/m3
Vapour pressure
5.33 kPa @ 19 °c (66.2 F)
Flash point (°C)
- 48 (-54.4 F) CC (Closed cup).
Auto Ignition Temperature (°C)
309 (588.2 F)
Flammability Limit - Lower(%)
1.4
8
4
/