Safety data sheet
Revision: 7
Revision date: 18/03/2015
SCC3 CONFORMAL COATING
No specific recommendations. Respiratory protection must be used if the airborne contamination exceeds the recommended
occupational exposure limit. If ventilation is inadequate, suitable respiratory protection must be worn. Wear a respirator fitted
with the following cartridge: Combination filter, type A2/P3. EN14387
SECTION 9: Physical and Chemical Properties
9.1. Information on basic physical and chemical properties
Appearance
Liquid. Aerosol.
Colour
Colourless.
Odour
Solvent.
Melting point
-24°C/-11.2°F
Initial boiling point and range
137 - 143°C/278.6 - 289.4°F @
Flash point
25°C/77°F OC (Open cup).
Upper/lower flammability or explosive limits
: 1.1 - 7
Relative density
0.780
Solubility(ies)
Insoluble in water.
Auto-ignition temperature
480°C/896°F
9.2. Other information
Volatility
Volatile.
SECTION 10: Stability and reactivity
10.1. Reactivity
There are no known reactivity hazards associated with this product.
10.2. Chemical stability
Stability
Stable at normal ambient temperatures.
10.3. Possibility of hazardous reactions
Not available. Will not polymerise.
10.4. Conditions to avoid
Avoid heat, flames and other sources of ignition.
10.5. Incompatible materials
Materials to avoid
Flammable/combustible materials. Strong oxidising agents.
10.6. Hazardous decomposition products
Fire creates: Vapours/gases/fumes of: Carbon monoxide (CO). Carbon dioxide (CO2).
SECTION 11: Toxicological information
11.1. Information on toxicological effects
7/15