Datasheet

Table Of Contents
Revision date: 18/02/2019 Revision: 1
Electronic Cleaning Solvent Plus
Usage precautions Read and follow manufacturer's recommendations. Wear protective clothing as described in
Section 8 of this safety data sheet. Keep away from food, drink and animal feeding stuffs.
Avoid exposing aerosol containers to high temperatures or direct sunlight. The product is
flammable. Keep away from heat, hot surfaces, sparks, open flames and other ignition
sources. No smoking. Avoid discharge to the aquatic environment. Do not handle until all
safety precautions have been read and understood. Do not handle broken packages without
protective equipment. Do not reuse empty containers. Do not spray on an open flame or other
ignition source. Do not pierce or burn, even after use. Spray will evaporate and cool rapidly
and may cause frostbite or cold burns if in contact with skin. Avoid contact with eyes. Avoid
inhalation of vapours and spray/mists.
Advice on general
occupational hygiene
Wash promptly if skin becomes contaminated. Take off contaminated clothing. Wash
contaminated clothing before reuse. Do not eat, drink or smoke when using this product.
Wash at the end of each work shift and before eating, smoking and using the toilet. Change
work clothing daily before leaving workplace.
7.2. Conditions for safe storage, including any incompatibilities
Storage precautions Store away from incompatible materials (see Section 10). Store in accordance with local
regulations. Keep away from oxidising materials, heat and flames. Keep only in the original
container. Keep container tightly closed, in a cool, well ventilated place. Keep containers
upright. Protect containers from damage. Protect from sunlight. Do not store near heat
sources or expose to high temperatures. Do not expose to temperatures exceeding
50°C/122°F. Bund storage facilities to prevent soil and water pollution in the event of spillage.
The storage area floor should be leak-tight, jointless and not absorbent.
Storage class Miscellaneous hazardous material storage.
7.3. Specific end use(s)
Specific end use(s) The identified uses for this product are detailed in Section 1.2.
SECTION 8: Exposure controls/Personal protection
8.1. Control parameters
Occupational exposure limits
pentane
Long-term exposure limit (8-hour TWA): WEL 600 ppm 1800 mg/m³
Propan-2-ol
Long-term exposure limit (8-hour TWA): WEL 400 ppm 999 mg/m³
Short-term exposure limit (15-minute): WEL 500 ppm 1250 mg/m³
Carbon Dioxide
Long-term exposure limit (8-hour TWA): WEL 5000 ppm 9150 mg/m³
Short-term exposure limit (15-minute): WEL 15000 ppm 27400 mg/m³
WEL = Workplace Exposure Limit
8.2. Exposure controls
Protective equipment
5/
16