Safety data sheet

Revision date: 04/12/2016 Revision: 0
Bloc'Lube Tamper Evident Seal Red
Ingestion Gastrointestinal symptoms, including upset stomach. Fumes from the stomach contents may
be inhaled, resulting in the same symptoms as inhalation.
Skin contact Prolonged contact may cause dryness of the skin.
Eye contact Irritating to eyes.
4.3. Indication of any immediate medical attention and special treatment needed
Notes for the doctor Treat symptomatically.
SECTION 5: Firefighting measures
5.1. Extinguishing media
Suitable extinguishing media The product is flammable. Extinguish with alcohol-resistant foam, carbon dioxide, dry powder
or water fog. Use fire-extinguishing media suitable for the surrounding fire.
Unsuitable extinguishing
media
Do not use water jet as an extinguisher, as this will spread the fire.
5.2. Special hazards arising from the substance or mixture
Specific hazards Containers can burst violently or explode when heated, due to excessive pressure build-up.
Flammable liquid and vapour. Vapours may be ignited by a spark, a hot surface or an ember.
Vapours may form explosive mixtures with air. Fire-water run-off in sewers may create fire or
explosion hazard.
Hazardous combustion
products
Thermal decomposition or combustion products may include the following substances:
Harmful gases or vapours.
5.3. Advice for firefighters
Protective actions during
firefighting
Avoid breathing fire gases or vapours. Evacuate area. Keep upwind to avoid inhalation of
gases, vapours, fumes and smoke. Ventilate closed spaces before entering them. Cool
containers exposed to heat with water spray and remove them from the fire area if it can be
done without risk. Cool containers exposed to flames with water until well after the fire is out.
If a leak or spill has not ignited, use water spray to disperse vapours and protect men stopping
the leak. Control run-off water by containing and keeping it out of sewers and watercourses. If
risk of water pollution occurs, notify appropriate authorities.
Special protective equipment
for firefighters
Wear positive-pressure self-contained breathing apparatus (SCBA) and appropriate protective
clothing. Firefighter's clothing conforming to European standard EN469 (including helmets,
protective boots and gloves) will provide a basic level of protection for chemical incidents.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Personal precautions No action shall be taken without appropriate training or involving any personal risk. Keep
unnecessary and unprotected personnel away from the spillage. Wear protective clothing as
described in Section 8 of this safety data sheet. Follow precautions for safe handling
described in this safety data sheet. Wash thoroughly after dealing with a spillage. Ensure
procedures and training for emergency decontamination and disposal are in place. Do not
touch or walk into spilled material. Evacuate area. Provide adequate ventilation. No smoking,
sparks, flames or other sources of ignition near spillage. Promptly remove any clothing that
becomes contaminated. Avoid inhalation of vapours and spray/mists. Use suitable respiratory
protection if ventilation is inadequate.
6.2. Environmental precautions
Environmental precautions Large Spillages: Inform the relevant authorities if environmental pollution occurs (sewers,
waterways, soil or air).
4/