Datasheet
Revision date: 20/08/2018 Revision: 1
SCC3 Conformal Coating Aerosol
Propan-2-ol <1%
CAS number: 67-63-0 EC number: 200-661-7 REACH registration number: 01-
2119457558-25-XXXX
Classification
Flam. Liq. 2 - H225
Eye Irrit. 2 - H319
STOT SE 3 - H336
4,5-Dichloro-2-octyl-2H-isothiazol-3-one <1%
CAS number: 64359-81-5 EC number: 264-843-8
M factor (Acute) = 100 M factor (Chronic) = 100
Classification
Acute Tox. 4 - H302
Acute Tox. 4 - H312
Acute Tox. 2 - H330
Skin Corr. 1C - H314
Eye Dam. 1 - H318
Skin Sens. 1A - H317
STOT SE 3 - H335
Aquatic Acute 1 - H400
Aquatic Chronic 1 - H410
The full text for all hazard statements is displayed in Section 16.
SECTION 4: First aid measures
4.1. Description of first aid measures
General information Get medical attention immediately. Show this Safety Data Sheet to the medical personnel.
Inhalation Remove affected person from source of contamination. Move affected person to fresh air and
keep warm and at rest in a position comfortable for breathing. Maintain an open airway.
Loosen tight clothing such as collar, tie or belt. When breathing is difficult, properly trained
personnel may assist affected person by administering oxygen. Place unconscious person on
their side in the recovery position and ensure breathing can take place.
Ingestion Rinse mouth thoroughly with water. Remove any dentures. Give a few small glasses of water
or milk to drink. Stop if the affected person feels sick as vomiting may be dangerous. Do not
induce vomiting unless under the direction of medical personnel. If vomiting occurs, the head
should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an
unconscious person. Move affected person to fresh air and keep warm and at rest in a
position comfortable for breathing. Place unconscious person on their side in the recovery
position and ensure breathing can take place. Maintain an open airway. Loosen tight clothing
such as collar, tie or belt.
Skin contact Rinse with water.
Eye contact Rinse immediately with plenty of water. Remove any contact lenses and open eyelids wide
apart. Continue to rinse for at least 10 minutes.
Protection of first aiders First aid personnel should wear appropriate protective equipment during any rescue. Wash
contaminated clothing thoroughly with water before removing it from the affected person, or
wear gloves. It may be dangerous for first aid personnel to carry out mouth-to-mouth
resuscitation.
4/
20