Specifications

Chapter 1: Overview of the ZVG
1 – 4
C. Jumpers and Indicators
The following is a descriptions of the jumpers and adjustments available on the
ZVG board.
Note: For simple operation it is not important to understand what each jumper does. The
following sections will describe how to set them up for the most commonly avail
-
able vector monitors.
Jumper Settings
(J3) Vector Table Selection. Select which firmware timing table to use.
(J4) Vector Draw Speed. Select vector drawing speed.
(J7) Linearity Correction Enable. Corrects for edge bloom.
(J8) Pincushion Correction Enable/Disable. Corrects for pincushioning.
(J8) Screen Size 2x Enable. Doubles screen size.
(J3) Setup enable / disable. Allows firmware / timing table updates.
Variable Adjustments
(R54,R42) X/Y Line Length Settings. Adjusts proper line length of vectors.
(R96,R69) X/Y Size Adjustments. Sets the screen size.
(R86,R78) X/Y Centering. Allows screen centering.
(R76) Trapezoid adjustment. In effect only if Pincushion is enabled, adjust for
proper vertical Trapezoid alignment.
LED Indicators
•(D3) Power.
(D4) Vector Draw Indicator / Error Blink Indicator.
Additional Software Adjustments (using ZVGTWEAK.EXE)
Starting and Ending point intensities.
Vector “Jump” speed. This is the time allowed to “Jump” from the endpoint of
one vector, to the start of the next.
Point Intensity. Sets the intensity of a point in relation to the intensity of vectors.
Minimum and Maximum Vector Brightness. Allows setting of Brightness and
Contrast levels.
Scaling. Sets the software controllable screen size value.