Symptom: No Green
On neck board:
R503 (open)
R513 (wrong value)
R520 (wrong value; was 22)
R530 (open)
Q501 (bad or base shorted to emitter)
broken wire at R513
jumper from R511 to R513 missing
On deflection board:
neck board connector wrong type
broken green wire from deflection board to neck board
Symptom: Only Green
On neck board:
Q503 (reversed or wired wrong)
Symptom: Green Too Bright
On neck board:
Q501 (collector shorted to emitter)
Symptom: No Green + Blue Is Red
On neck board:
R500 (shorted to R529 or shorted to R502)
Symptom: Green Is Red
On neck board:
R502 (shorted to R500)