CAN address
Every programmable wall station has to have a unique CAN address
to be identified on the CAN-Bus. The usable address range is: 1 (01
hex) up to 250 (FA hex). The PWS-C’s ADDRESS DIP switch (see
page 6) allows specifying the CAN address by setting a two-digit
hexadecimal number. A table of possible CAN addresses and
corresponding DIP-switch settings is provided on page 45.
The default CAN address when shipped is 0 (00 hex).
CAUTION:
To prevent network faults, each CAN address may exist once only throughout a system.
Conflicts on the network would be the result.
NOTES:
Various programmable wall stations of a system can be easily configured when their
CAN addresses are in consecutive order.
A programmable wall station is disconnected from the CAN-Bus when its CAN address
has been set to 0.
If the setting of the DIP-switch is changed, the CAN status LED lights up for 3 seconds.
The new setting becomes effective when the CAN status LED is dimmed.