User manual

Electro-Voice EVA Series User Manual 33
6.4 Special Rules when Flying EVA-2151D Subwoofer Modules
EVA-2151D subwoofers may ONLY be flown from an EVA-EG2 grid. Because the EVA-2151D modules
have six rigging points instead of four, the maximum load ratings are higher, but also require special condi-
tions to achieve. Please read, understand and observe the following:
1. When flying EVA-2082S full-range modules below EVA-2151D subwoofer modules, the
maximum number of EVA-2151D modules is TWO and the maximum number of EVA-
2082S modules is FIVE. A bottom pull-up point may be used as long as the maximum
angle on the grid does not exceed 45° and the maximum pull angle between suspension
lines does not exceed 60°. Maximum single-point column weight when using EVA-2151D
subwoofers is 840 lb (381 kg).
2. When flying EVA-2151D subwoofer modules as a stand-alone subwoofer array using the
center attachment point on the spreader bar(s), the maximum number of EVA-2151D mod-
ules is FOUR, even if two spreader bars are used. For extreme down angles, a second
EVA-EG2 grid may be attached at the bottom of the array for use as a pull-up point as long
as the maximum pull angle between suspension lines does not exceed 60°.
3. When flying FIVE or more EVA-2151D modules, use only the two outermost attachment
holes on the spreader bar. If two spreader bars are used, the two outermost attachment
holes must be used ON EACH BAR. A maximum vertical column of EIGHT EVA-2151D
modules is permissible under these conditions if the column is kept perpendicular to the
ground. The maximum suspended column weight of EVA-2151D subwoofers in a stand-
alone subwoofer array with 0° of inclination (tilt) angle using both outer attachment points
on the spreader bar is 1,470 lb (667 kg). See Figure 24.
6.0 Rigging-Strength Ratings and Safety Factors (cont’)
Figure 24:
EVA-EG2 grid with more than (4) EVA-2151D’s in a straight (vertical)
array must use outer holes of spreader bar
Any Array with more
than (4) EVA-2151D’s
must use the two
outermost attach-
ment holes on the
spreader bar
Any Array with more
than (4) EVA-2151D’s
must use the two
outermost attach-
ment holes on the
spreader bar
NEVER ATTEMPT TO SUSPEND EVA SYSTEMS OVERHEAD BY ANY OTHER METH
OD THAN THE USE OF EVASG2, EVAEG2 OR EVACG GRIDS AND SPREADER
BARS AS OUTLINED IN THIS MANUAL! EVA1151D MODULES MAY BE SUSPEND
ED FROM INVERTED EVA1151D TIE PLATES ONLY IN CONJUNCTION WITH AN EVAGXB
SPREADER BAR SOLD SEPARATELY.