User manual
Electro-Voice EVA Series User Manual 33
6.4 Special Rules when Flying EVA-2151D Subwoofer Modules
EVA-2151D subwoofers may ONLY be flown from an EVA-EG2 grid. Because the EVA-2151D modules
have six rigging points instead of four, the maximum load ratings are higher, but also require special condi-
tions to achieve. Please read, understand and observe the following:
1. When flying EVA-2082S full-range modules below EVA-2151D subwoofer modules, the
maximum number of EVA-2151D modules is TWO and the maximum number of EVA-
2082S modules is FIVE. A bottom pull-up point may be used as long as the maximum
angle on the grid does not exceed 45° and the maximum pull angle between suspension
lines does not exceed 60°. Maximum single-point column weight when using EVA-2151D
subwoofers is 840 lb (381 kg).
2. When flying EVA-2151D subwoofer modules as a stand-alone subwoofer array using the
center attachment point on the spreader bar(s), the maximum number of EVA-2151D mod-
ules is FOUR, even if two spreader bars are used. For extreme down angles, a second
EVA-EG2 grid may be attached at the bottom of the array for use as a pull-up point as long
as the maximum pull angle between suspension lines does not exceed 60°.
3. When flying FIVE or more EVA-2151D modules, use only the two outermost attachment
holes on the spreader bar. If two spreader bars are used, the two outermost attachment
holes must be used ON EACH BAR. A maximum vertical column of EIGHT EVA-2151D
modules is permissible under these conditions if the column is kept perpendicular to the
ground. The maximum suspended column weight of EVA-2151D subwoofers in a stand-
alone subwoofer array with 0° of inclination (tilt) angle using both outer attachment points
on the spreader bar is 1,470 lb (667 kg). See Figure 24.
6.0 Rigging-Strength Ratings and Safety Factors (cont’)
Figure 24:
EVA-EG2 grid with more than (4) EVA-2151D’s in a straight (vertical)
array must use outer holes of spreader bar
Any Array with more
than (4) EVA-2151D’s
must use the two
outermost attach-
ment holes on the
spreader bar
Any Array with more
than (4) EVA-2151D’s
must use the two
outermost attach-
ment holes on the
spreader bar
NEVER ATTEMPT TO SUSPEND EVA SYSTEMS OVERHEAD BY ANY OTHER METH
OD THAN THE USE OF EVASG2, EVAEG2 OR EVACG GRIDS AND SPREADER
BARS AS OUTLINED IN THIS MANUAL! EVA1151D MODULES MAY BE SUSPEND
ED FROM INVERTED EVA1151D TIE PLATES ONLY IN CONJUNCTION WITH AN EVAGXB
SPREADER BAR SOLD SEPARATELY.